13
installation island hood
The key dimensions are indicated on page 10.
Set the height of the telescopic pipe within
the allowable range.
It is advisable to suspend the hood with the
help of an assembly lift. If there is no lift
present, it is advisable to carry out the
mounting with more than one person.
Position the discharge and the electrical
connection in such a way that it will be easy
to hook up the hood.
marking
- Mark out the holes on the ceiling using
the template. Make sure that one of the
holes is at the front. Mark the drill hole for
the mounting plate too.
- Drill the holes (5 x 10 mm).
hanging telescopic pipe
- Fix the plugs and the studs to the
ceiling. Screw the studs 20 mm into the
plugs in the ceiling.
The locking hole should only have a plug
placed in it.
- Screw the washers and nuts onto the
bolts up to 6 mm under the ceiling.
- Put the top telescopic pipe over the studs.
Screw down the washers and the nuts.
Fasten the mounting plate to the ceiling
with a safety screw.
fastening glass plate
- Place the glass plate on the filter holder.
The arrow should point in the direction of
the control panel. Slide the filter holder
into the extractor hood.
- Screw the 5 nuts on loosely. Adjust the
glass plate and fasten it.
measuring
- Slide the lower telescopic pipe (with
motor and glass plate) over the already-
fitted upper telescopic pipe.
- Determine the length of the telescopic
pipe. Remember the minimum height
above the hob.
- Mark the drill holes and slide the two
sections apart again.
- Drill fixing holes (3,7 mm) at the side of the
upper telescopic pipe using the drill bit
supplied. Deburr the holes.
fitting extractor hood
- Fit the connecting cable and the
discharge hose from the inside. Make
sure that there are no kinks in the
discharge hose.
- Slide the hood over the telescopic pipe.
Secure it with the three screws.
installation wall hood
fitting extractor hood
- Slide the extractor hood onto the telescopic
pipe.
- NB: The upper telescopic pipe slides
between the motor housing and the lower
telescopic pipe (2 mm clearance).
- Adjust the telescopic pipe and fasten the
extractor hood with the washers and nuts
supplied.
- Place the glass plate on the filter holder.
The arrow should point in the direction of
the control panel. Slide the filter holder into
the extractor hood.
- Screw the 5 nuts on loosely. Adjust the
glass plate and secure it.
- Connect up the light cable.
- Attach the filter to the chain and secure the
filter by turning it clockwise.