507731
7
Zoom out
Zoom in
Previous page
1/37
Next page
Installation instructions S-HR series page 7
6 Connecting the boiler
The boiler has the following connection pipes;
- The central heating pipes.
These can be connected to the installation by means
of compression fittings;
- The gas pipe.
It is provided with a female thread into which the tail
piece of the gas valve can be screwed;
- The condensation drain pipe.
It consists of an oval 24 mm plastic pipe. The drain
pipe can be connected to this by means of an open
connection. If the open connection is fitted in a
different location, then the pipe can be lengthened
by means of a 32 mm PVC sleeve;
- The flue gas exhaust system and air supply system.
It consists of a concentric connection 80/125 mm.
- Cold and hot water pipes.
These consist of 15 mm copper pipe and can be
connected to the installation by means of
compression fittings.
When removing the plastic sealing caps from
the pipes, contaminated testing water can be
released.
It is advisable to spray-clean all of the unit’s
connecting pipes and/or to spray-clean/blow-
clean the installation before connecting it to
the unit.
connection diameters table 2
boiler pipes bottom figure 2
g f r c e k w
tinufoepyt
RH-S
51
RH-S
42
RH-S
T42
RH-S
53
RH-S
T53
RH-S
15
RH-S
T15
RH-S
06
tsuahxesageulf/ylppusrianoitsubmoc
mm521/08521/08521/08521/08521/08521/08521/08521/08
g-epipsag
edisni"½edisni"½edisni"½edisni"½edisni"½edisni"¾edisni"¾edisni"¾
f-epipwolfgnitaehlartnec
mm8282828282535353
r-epipnrutergnitaehlartnec
mm8282828282535353
c-epipegrahcsidnoitasnednoc
mm4242424242424242
e-epiplessevnoisnapxe
mm22222222
k-epipretawdloc
mm515151
w-epipretawtoh
mm515151
d-WHDepipnruter
mm828282
g f r c e d
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG Blauwe Engel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG Blauwe Engel in the language / languages: English as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG Blauwe Engel

ATAG Blauwe Engel Manual - Dutch - 2 pages

ATAG Blauwe Engel Installation Guide - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info