5 Filling the heating installation
If you want to top up the heating installation, proceed as follows:
(If in doubt, check with your installer)
1 Connect the lling hose to the cold water tap;
2 Fill the hose completely with drinking water;
3
Connect the lled hose to thelling and draining valve of the heating installation;
4 Open the lling and draining valve;
5 Open the cold water tap;
6 Slowly ll the CH installation to 1,5-1,7 bar:
Press the i-key until A6 appears (water pressure). The value on the display
increases;
7 Close the cold water tap;
8 The code C1 05 will appear on the display the moment the pressure
exceeds Venting program of approx. 7 min. becomes active;
9 Bleed the entire CH installation: start at the lowest point;
10 Check the water pressure and if necessary top off until 1.5 to 1.7 bar
11 Make sure the cold water tap and lling and draining valve are closed;
12 Disconnect the lling hose;
After the venting program (c1 05) of approx. 7 minutes has ended, the boiler
will be operational again.
Check the water pressure regularly and top it up if necessary. The operating
pressure in the system under cold conditions should be between 1.5 and 1.7
bar.
It may take some time before all the air has disappeared from a newly lled
installation. Especially in the rst week, sounds may be heard that indicate air. The
automatic air vent in the boiler will let this air escape, causing the water pressure
to drop during this period and water will need to be relled again.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG A244EC-CW4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG A244EC-CW4 in the language / languages: English as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG A244EC-CW4

ATAG A244EC-CW4 User Manual - German - 60 pages

ATAG A244EC-CW4 Manual - Dutch - 2 pages

ATAG A244EC-CW4 User Manual - Dutch - 60 pages

ATAG A244EC-CW4 Installation Guide - Dutch - 44 pages

ATAG A244EC-CW4 User Manual - Dutch - 16 pages

ATAG A244EC-CW4 Installation Guide - Dutch - 36 pages

ATAG A244EC-CW4 User Manual - French - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info