673158
11
Zoom out
Zoom in
Previous page
1/20
Next page
Inst.296 Viron eVo Series Pool & Spa Heater V07_16
12
600
Approved gas
termination cowl
1500
Upper grille for fresh air
ventilation
Lower grille for fresh air
ventilation
Do not install spa blowers in the same room as a gas heater. This is potentially dangerous to spa users.
Do not store chemicals or fuel in the same room as the gas heater. This may cause fire or explosion.
When installing in a garage the Viron Series Heater must be installed 450 mm above floor level.
ELECTRICAL CONNECTION
The heater is supplied with a standard 10 amp 3 pin plug for connection to a 240V 10 amp GPO. All pool or spa
equipment connected to mains power should be protected by an RCD circuit breaker.
GAS CONNECTION
The gas connection is on the right hand side of the heater. A 22mm M.I. connection is provided for gas line
connection. An approved manual shut off valve must be installed in the gas fitting line before the heater.
The gas fitting line should be installed by an authorised person and comply with local regulations and Australian
Standard code AS/NZ 5601. The gas line from the meter will usually be of a larger size than the gas inlet
connection.
The heater gas valve has a built in pressure regulator and ⅛” pressure test point. On starting the heater, a
manometer must be used and the supply inlet pressure checked while the heater is running against the heater
data plate. Incorrect inlet pressures may void warranty and may result in service charges, should service be
required. Gas valves are preset and should only be adjusted by trained Astral Pool technicians.
PRESSURE SWITCH ADJUSTMENT
The Viron Pool Heater incorporates a water pressure switch which allows the burner to operate only when the
circulating pump is operating. The pressure switch is designed to operate with the heater installed up to 1.2
metres above or below the surface level of the pool or spa. For installations outside these limits, a flow switch
should be installed.
It is imperative that the following be undertaken by the person who is commissioning (first starting) your pool or
spa heater. On initial start up of the heater it may be necessary to adjust the water pressure activation switch.
This switch is located behind the top right hand side panel and is screwed into the water manifold. The pressure
switch is a safety device, designed to allow operation of the heater only when the circulating pump is on and there
is sufficient water flow through the heater. It must shut the heater down immediately the pump is switched off.
To check the operation of the switch:
1. Connect the heater to mains power supply and turn power on. The thermostat should not yet display “θ”.
2. Turn on pump. The thermostat should now display “θ”.
3. Turn pump off. The thermostat should no longer display “θ”.
4. If display does not respond in this way, adjust the pressure switch as detailed below. If display responds
correctly, perform a final check with the heater operating.- See the section below titled “Starting the heater”
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool Viron eVo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool Viron eVo in the language / languages: English as an attachment in your email.

The manual is 0,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info