Parámetro Nombre Rango Observaciones
d1 La temperatura del agua de entrada -9-99 Valordelapruebareal
d2 Temperatura del agua de salida -9-99 Valordelapruebareal
d3 Temperatura ambiente -F(-30)-70 Valordelapruebareal
d4 Temperatura de retorno de gas -F(-30)-70 Valordelapruebareal
d5
Temperatura del evaporador
-F(-30)-70 Valordelapruebareal
d6 Temperatura de escape de gas 0-C5(125) Valor de la prueba real
d7 Pasos de la válvula de expansión
electrónica
0-99 N*5
d8 Frecuencia de operación del compresor
IMPULSO: 65,70,75Hz
ECOLOGÍA: 50,55,60Hz
TRANQUILO: 30,35,40,45Hz
0-99Hz Valordelapruebareal
d9 Corriente del compresor
0-30A Valor de la prueba real
NOTA
Recuperar la configuración predeterminada de fábrica
Pulsación larga
y al mismo tiempo para 10 segundos para recuperar la configuración
predeterminada de fábrica, se mostrará "0000" durante 5 segundos todavía es necesario para protegerse
contra cortocircuitos dentro de la unidad también se requiere .
(1) Cuando la BdC deja de estar en funcionamiento, en 30 segundos, la bomba de agua se apagará
automáticamente.
(2)El controlador LED puede controlar la bomba de filtración, un avez conectado mediante un cable
adicional, al dispositivo de la bomba en la posición del terminal "PUMP".
(3) Es necesario poner un dispositivo extra de 3 fasesa para la bomba de filtración agua de trifásica.
189


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool PRO-ELYO INVERTER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool PRO-ELYO INVERTER in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 10,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info