ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEMASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
© ASTRALPOOL 2015 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
Pag:
21
ENGLISH
ENGLISHENGLISH
ENGLISH
5.10.
5.10. 5.10.
5.10. POOL / SPA CONTROL (OPTIONAL)
POOL / SPA CONTROL (OPTIONAL)POOL / SPA CONTROL (OPTIONAL)
POOL / SPA CONTROL (OPTIONAL)
Pool / Spa control allows the heat pump to heat water on a pool or a Spa or both alternatively.
The unit is able to control the 3-way-valves used to configure the hydraulic circuit on Pool or
Spa modes.
Connection depends on water hydraulic system layout. Two main configurations can be
considered:
Two independent filtration systems (three 3-way-valves). See IMAGE 7 (page 187).
One common filtration system (two 3-way-valves). See IMAGE 8 (page 188).
Pool / Spa optional consists of an extra electronic board which is assembled directly to the main
board and a 24V AC power transformer that will power on the hydraulic 3-way-valves.
See IMAGE 9 (page 189)
In order to control the configuration of the hydraulic system, the 3-way-valves must be
connected to the Pool-Spa control PCB. Whether 3 or 2 valves hydraulic configuration system is
present, connect the valves to terminals marked as V1, V2 and V3, taking into account normally
close (N.C.) / normally open (N.O.) and common (COM) terminals. See IMAGE 10 (page 189).
Pool / Spa board also includes a filtration pump control connector in order to manage Spa
filtration system in case there are two filtration systems: one for the pool (controlled by main
board) and another one for the spa. See IMAGE 10 (page 189).
5.11.
5.11. 5.11.
5.11. EOM ENERGY EFFICIENT MODE
EOM ENERGY EFFICIENT MODEEOM ENERGY EFFICIENT MODE
EOM ENERGY EFFICIENT MODE
While in EOM efficiency mode, the APHeat heat pump continuously checks energy available in
the environment as well as the thermal inertia of the water and will decide whether it is
efficient to heat the water pool or not.
Keep in mind that all energy efficiency modes have the advantage of savings in equipment
operating costs, but also involve some drawbacks.
Pictures 11 & 12 describe the operation of the APHeat Heat pump in EOM mode:
IMAGE 11 (page 190) describes the operation of a heat pump for 3 days, configured to maintain
water set point, ie without any energy efficiency method activated. As we can see, the unit
works even when the available energy in the environment is low (the unit has a weak
performance), as it has been configured to maintain the set point temperature under all
circumstances.
By contrast, IMAGE 12 (page 190) shows operation of the same unit during the same 3 days, but
with the EOM energy efficiency method activated. As we can see, there are certain time periods
when the unit is not allowed to run, because the unit knows that there is little energy available
in the environment. At the time when there is available energy, the unit will work again.
The great advantage of this mode is that we can obtain equipment operating cost savings up to
40%
The drawback is that in periods when low energy is available in the environment, since the unit
does not work, the pool water temperature will drop. But presumably, in these periods of low
energy, the user of this pool is not very prone to bathe as little energy in the air means cold air.
When the air temperature rises again and the machine detects that it is efficient to operate, it
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool ASTRALPOOL HEAT II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool ASTRALPOOL HEAT II in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 8,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info