628507
35
Zoom out
Zoom in
Previous page
1/112
Next page
A
DVANCED
I
NSTALLATION
ASPI Digital - The Sound of DSP Technical Support: 404.892.3200 33
calibration. For Calibration Step 3, the S
ETUP
LED will blink three times per
period.
For this step, you will need a live connection to a remote conferencing site (or
two sites if you are configuring the EF1210 for two AEC reference inputs).
If you are configuring the EF1210 for operation with one AEC reference
input, you will calibrate the AEC A signal.
If you are configuring the EF1210 for operation with two AEC reference
inputs, you will calibrate both the AEC A and the AEC B signals.
3.2. Press R
EF
S
ELECT
to select between AEC A and AEC B. This will be indicated
by the front panel AEC A and AEC B LEDs. During this step, all other LEDs
(I
NPUT
C
HANNEL
) will be extinguished.
3.3. Have the person at the remote end of the conferencing link sit at a normal dis-
tance from a microphone and talk at a normal level while you observe the signal
activity on the R
EMOTE
S
IGNAL
L
EVEL
M
ETER
.
3.4. Adjust the AEC Reference Input by pressing the L
EVEL
A
DJUST
buttons until the
first yellow (0 dB) LED lights regularly during normal speech at the remote end,
and the second yellow LED flickers occasionally.
3.5. If you are calibrating two AEC Reference Inputs, switch to the other by pressing
R
EF
S
ELECT
and repeat the calibration for the second reference signal.
Refer to Figure 13 on page 33.
C
ALIBRATION
S
TEP
4: C
ALIBRATING
FOR
P
LAYBACK
AND
R
ECORD
4.1. Once the AEC Reference Inputs have been calibrated, press A
UX
I
N
L
EVEL
/
S
ETUP
again to switch to Playback/Record calibration. For Calibration Step 4,
the S
ETUP
LED will blink four times per period. This step calibrates the T
O
Figure 13. Calibrating AEC Reference Inputs
-12 -7 -3 0 3 20 dB -12 -7 -3 0 3 20
AUX IN
LEVEL
REF
SELECT
INPUT
SELECT
SETUP
AEC
A
AEC
B
12345678
INPUTPOWER REMOTE
MUTE
ALL
LEVEL
ADJUST
SETUP
STEP 3.4: adjust
level until person
talking at remote
site rarely flickers
second yellow LED
STEP 3.2: press
to select
reference input
source
AEC A input selected
AEC B input selected
LED blinks three
times for AEC
Reference calibration
Caution!
If you skip this calibration step, you will compromise the
performance of the EF1210. The audio coming from the
remote end may be too low, so if you turn up the loud-
speaker to compensate, the acoustic gain will be affected.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aspi EF1210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aspi EF1210 in the language / languages: English as an attachment in your email.

The manual is 0,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aspi EF1210

Aspi EF1210 Additional guide - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info