557781
14
Zoom out
Zoom in
Previous page
1/32
Next page
- 14 -
3.3.2 Restore (restore message)
The input numbers are displayed on the keypad which will send a restore.
RP and YS do not send a restore [signal], even if the input is set to restore.
1. Press £ or ¢ until the cursor is placed below the input to be altered. [12345678]
2. Press 0 to disable a restore for that input. [12.45678]
3. This option can be reversed by repeating steps 1 and 2.
3.3.3 Trigger NO / NC
The input numbers displayed on the keypad are normally open inputs. If an N/O input closes (short-circuiting
to negative), an activation is reported. The restore message is reported when the input re-opens. These
reactions can be reversed by setting an input to be normally closed.
1. Press ¢ or £ until the cursor is under the input to be altered [12345678].
2. Next press 0 to make the selected input to operate as normally closed. [12. 45678].
3. This option can be reversed by repeating steps 1 and 2.
3.3.4 Delayed events
The input numbers are displayed on the keypad which must be active for a certain length of time before they
can be reported. This is programmed in [
Event delay
].
It is not possible to delay the restore of events.
3.3.5 Delay ss
This is the delay period (set at between 1 and 99 seconds) during which a signal must be present for a
certain delayed event before the activation is reported.
If the alarm condition is restored before the delay has expired, the activation is not
reported.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech TD8803 TD8412 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech TD8803 TD8412 in the language / languages: English as an attachment in your email.

The manual is 0,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info