557695
154
Zoom out
Zoom in
Previous page
1/167
Next page
154
CS175-275-575-875 Installation Guide
Cancel
If enabled, the CSx75 sends a cancel report if when the system is disarmed.
Dialler Delay must be enabled in the Characteristic Select in locations 127 to
206.
See
Location 34
on page 65 for more information.
Chime
An audible signal that a door has been opened.
Code
A series of four to six numbers that allow access to the system.
Code Required Options
The CSx75 can be programmed to require a code for bypassing zones and/or
initiating a download using the -9-8 or -9-9 function.
See
Location 34
on page 65 and
Location 53
on page 71 for more information.
Communication formats
The CSx75 can report in multiple formats. It is recommended that you use
Contact ID or SIA formats if possible. If you wish to report to a pager or in a
4+2 format to a central station, you must program each code to be reported.
See
Location 69
to
Location 121
, starting on page 77, and
Location 127
to
Location 206
, starting on page 80, for more information.
Configuration
The arrangement of the hardware and software of the security system set up
for a particular installation.
Delayed restore
The CSx75 can be programmed to send alarm and restore reports as soon as
they occur, or wait until the siren time has expired.
See
Location 51
on page 70 for more information.
Disarmed
The security system is off.
Display
The window on the keypad.
Double knock
A zone which generates an alarm only when it is opened twice within a
programmed time frame.
Double open
The length of time the double knock zone remains open after the first event. If
a second event is generated within the set time, an alarm is generated.
Duress code
If a duress code is programmed, the CSx75 sends a duress signal whenever
the panel is armed or disarmed with this code. If open/close reports are sent,
the user code is 254.
See
Location 56
on page 72 for more information.
Dynamic battery test
The CSx75 can be programmed to perform a dynamic battery test for a
selected duration the first time the panel is armed or disarmed every day, as
well as by pressing 40 Test Function. If the panel is not armed or disarmed
during the day, it performs the test at midnight. The CSx75 can also be
programmed to perform a missing battery test every 12 seconds.
See
Location 51
on page 70 and
Location 52
on page 71 for more information.
EN50131
European security standard. It involves a set of rules which limits the amount of
access the installer has to a user's security system.
Entry route
The route taken to enter and reach the control unit to disarm the system.
Entry time
Time within which the user must disarm the system before a full alarm occurs.
154


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech CS575 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech CS575 in the language / languages: English as an attachment in your email.

The manual is 2,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech CS575

Aritech CS575 User Manual - Dutch - 23 pages

Aritech CS575 Installation Guide - Dutch - 166 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info