557694
155
Zoom out
Zoom in
Previous page
1/167
Next page
CS175-275-575-875 Installation Guide 155
Entry-guard
A unique low level arming mode that reduces the most common source of
false alarms. When armed, the opening of any zones designated as entry-
guard zone activates the keypad sounder and starts the entry delay before
creating an alarm. All other zones function as normal. This arming mode
encourages system owners to use their system more frequently when the
premises are occupied.
See
Location 127
to
Location 206
, starting on page 80, for more information.
Event log
A list of events that have occurred in the security system. They are held in a
sequential event buffer with a time and date stamp. Up to 100 events are kept
in the rolling log. The log is never full, but overwrites the oldest entries with
new data.
Exit error
If enabled, the CSx75 sends an exit error report if an entry/exit zone is faulted
at the instant the exit delay expires. This report is sent along with the user
number that armed the system, if the panel is not disarmed before the entry
delay expires. Even if this feature is not enabled, the siren sounds if any
entry/exit zone is faulted at the instant the exit delay expires.
See
Location 34
on page 65 for more information.
Exit route
The route taken to leave the secured area after arming.
Exit terminator
This allows the user to program the control unit to arm as soon as it detects
that the door used to exit the premises has closed.
Exit time
Time allowed when exiting the building after turning on the security system
before an alarm is reported.
Expander trouble
The CSx75 reports expander trouble to the central station if enabled. The
keypads are considered expanders.
See
Location 49
to
Location 51
, starting on page 69, for more information.
Fail to Communicate
The system has failed to communicate with the central station. If enabled, a
Fail to Communicate code is reported when the next report is successfully
communicated.
See
Location 51
on page 70 for more information.
Final door set
This allows the user to program the control unit to arm as soon as it detects
that the door used to exit the premises has closed.
Fire alarm verification
When enabled, the CSx75 verifies a fire alarm by requiring more than one trip
on a smoke detector within a specified time before creating an alarm.
See
Location 52
on page 71 for more information.
First to open/Last to
close
In a multipartitioned system, the first area opened is reported to the central
station and a log is kept recording when the other areas are opened. When
closing the areas, a log is kept of all the areas as they are closed and only
when the last open area is closed and a report is sent to the central station. In
a single partitioned system, a report is sent when the system is opened and
closed.
See
Location 34, Segment 3
on page 65 for more information. Use location 51
with multi-area system with only one account.
155


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech CS275 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech CS275 in the language / languages: English as an attachment in your email.

The manual is 2,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech CS275

Aritech CS275 Additional guide - Dutch - 2 pages

Aritech CS275 Additional guide - Dutch - 20 pages

Aritech CS275 User Manual - Dutch - 23 pages

Aritech CS275 Installation Guide - Dutch - 166 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info