CS175-275-575-875 Installation Guide
6 WIRING ZONES
6.1 General
The control unit inputs are set up as standard EOL (4K7) freely programmable zones.
However, by programming the zones as dual loop, all control unit zone inputs can be
programmed to provide alarm and tamper indications on the same zone.
6.2 Dual wiring
One zone includes both alarm and tamper wiring.
The alarm devices are wired in series and a 4K7 resistor is fitted in parallel across the
closed circuit contacts.
The tamper contacts are wired in series with a 4K7 EOL resistor.
All devices closed - loop resistance is 4K7.
Tamper device open - loop is an open or short circuit.
Alarm device open - loop resistance is 9K4 (EOL resistor PLUS parallel resistor).
4K7
4K7
E.O.L.
1
Zone terminal
3
Alarm contact
2
Sensor
4
Tamper contact
6.3 Single wiring
Two zones are required, one zone for alarm and one zone for tamper. The tamper
contacts are wired in series with a 4K7 EOL resistor.
4K7
E.O.L.
4K7
E.O.L.
1
Zone terminal
3
Alarm contact
2
Sensor
4
Tamper contact
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech CS175 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech CS175 in the language / languages: English as an attachment in your email.

The manual is 2,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech CS175

Aritech CS175 Installation Guide - Dutch - 166 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info