702280
16
Zoom out
Zoom in
Previous page
1/28
Next page
12 ATS125x 4-Door DGP Installation Manual
The zone numbers in Table 6 on page 11 refer to the physical zone numbers on the
ATS125x PCB.
The system zone numbers relating to these functions for each of the ATS125x can be
found in Table 4.
Door numbering
Door numbers are determined by:
The RAS or reader address when connected to the ATS system databus (doors 1
to 16).
4-door DGP address (doors 17 to 64).
Doors 1 to 16 are reserved for RAS 1 to 16 and are connected to the ATS system
databus. These only provide basic access control (door opening).
Doors 17 to 64 are used for door numbers and are controlled by a 4-door DGP
(ATS125x). These doors provide enhanced access control functions (such as anti-
passback).
Table 7: Door numbers allocated per DGP
Device address / Door number
RAS 1 to 16 1 to 16 (door open only)
Door
1 2 3 4
DGP1 17 18 19 20
DGP2 21 22 23 24
DGP3 25 26 27 28
DGP4 29 30 31 32
DGP5 33 34 35 36
DGP6 37 38 39 40
DGP7 41 42 43 44
DGP8 45 46 47 48
DGP9 49 50 51 52
DGP10 53 54 55 56
DGP11 57 58 59 60
DGP12 61 62 63 64
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS1250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS1250 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech ATS1250

Aritech ATS1250 Additional guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info