6 ATS1201 Installation Guide
!
!
It is recommended that where the distance between the
arming station and the nearest device is more than 100
meters, a separate power supply must be used to
power the arming station.
To power the arming station, do not connect ‘+’ from
the system databus. Connect '+' of the local power
supply to '+' on the arming station and connect 0 volts
from the power supply and 0 volts from the system
databus to the arming station terminal marked ‘-’.
See also Cabling ATS1201 on page 5.
11. Mains connection
Make sure that before connecting the mains power, the
mains power supply is disconnected (see page 4).
When installing the mains power, use strain relieves like
cable ties and coupling PG16’s to ensure proper wiring.
In all cases, local regulations should be applied.
12. Earthing (see )
WARNING!
Correct earthing procedures must be
followed
Earthing of one cabinet containing several
devices.
All devices designed for the system have earth
connections via metal studs to the metal housing. Take
care, that these metal studs make good connection to
the housing (beware of paint).
The earth connections of every piece of equipment in
the system, can be used for connecting the shielding of
shielded cables. If a device is placed in a plastic
housing the earth lug of this device does not have to be
connected.
Earthing panels in a single building.
In one building several cabinets or devices are earthen
to safety ground.
The safety earth of this building has to be checked by a
licensed contractor.
Earthing panels in more buildings.
If the wiring extends to separated buildings, more than
one common earth system will be used. Use
isolator/repeaters ATS1740 to isolate the system
databus. In this way the system is protected against
variations in earth potential.
Shielding
The shielding of all shielded cables used in the system,
should only be connected at ONE side to one common
earthing point in a building (see Fig. 3) If a shielded
databus cable is routed via more than one plastic
device the shielding from incoming and out-going cable
has to be connected.
Explanation of fig.
(1) Mains power with local earth
(2) Mains power connector
(3) System databus
(4) Earth lug
(5) Building 1
(6) Building 2
(7) Device in metal housing
(8) Device in plastic housing
(9) ATS2000/3000/4000/4500 control panel
13. Connecting the data gathering
panel to a control panel
Refer to the control panel installation guide for
instructions.
14. Zone and output numbering
Control panel 1 - 16 DGP8 129 - 144
DGP1 17 - 32 DGP9 145 - 160
DGP2 33 - 48 DGP10 161 - 176
DGP3 49 - 64 DGP11 177 - 192
DGP4 65 - 80 DGP12 193 - 208
DGP5 81 - 96 DGP13 209 - 224
DGP6 97 - 112 DGP14 225 - 240
DGP7 113 - 128 DGP15
241 -
256/255*
Output numbering (*max. 255 outputs)
A DGP can have a maximum of 16 outputs available as
relays or open collectors outputs. The output numbers
are the same as the 16 zone numbers allocated to the
DGP address.
Important:
All outputs are available on the control panel for
programming. However you can only fit 16 relay cards
(ATS1811 or ATS1820), taking into consideration the
load on the Clock-out Interface of the output expansion.
ATTENTION!
If six or more relay cards are used, an
external power supply is required to power
the relay cards
Zone numbering (256 zones)
The ATS 1201 has 8 zones that can be expanded using
the ATS 1202 (8 zones) to a maximum of 32 zones. If
the number of zones exceeds 16, then the zones are
taken from the next DGP address and DGP ceases to
exist.
e.g. DGP 1 has 24 zones (zones 17 to 40). The
next DGP in the system must now be addressed and
polled as DGP 3, because zones 33 to 40 on DGP 1
have taken from DGP 2.
The unused zone numbers in the system (zones 41 to
48) must be programmed in the zone database as Type
0.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS 1201 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS 1201 in the language / languages: English, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info