655849
49
Zoom out
Zoom in
Previous page
1/68
Next page
1.5. PROfessional TECH PTEC steatite range - HPC - QUIE
1.5.a. Definition of the range
Heating element: Steatite heating element
located inside a bush
Anti-corrosion protection: Enamelled boiler +
PROfessional TECH anode - HPC - QUIE
The exclusive PROfessional TECH system solution
is an anodic anti-corrosion electronic protection
system with a modulated current. It ensures
maximum durability in terms of the boiler used
in the water heater, regardless of whether more
or less aggressive water is used. The electronic
circuit creates a difference in potential between the
boiler and the titanium electrode, so that optimal
boiler protection is guaranteed, thereby preventing
its corrosion.
Picture 3- Steatite heating element + PROfessional TECH
anode
1.5.b. Technical features
See page 6.
INSTALLATION
1. Legal obligations and recommendations
relating to product installation
Before installing this appliance, please read the
instructions contained in this manual carefully.
Failure to observe these instructions may lead to
the guarantee becoming void.
1. All product installation and maintenance work
must only be performed by qualified professionals.
Current national legislation must be observed. In
particular, all regulations relating to water heaters
must be fully observed.
2. The manufacturer shall not be held liable for
any damage caused by unprofessional or improper
installation, or by failure to comply with the
instructions contained in the user manual.
to the sewage system is compulsory in all
instances.
To avoid excessive energy consumption,
we recommend that the water heater is
positioned as close as possible to the
hot water drawing points (recommended
distance: no greater than 8 metres).
A : Magnesium anode / B : Spike / C : Immersion heating element / D : Plate / E : Bush / F : Steatite heating element /
G : PROfessional TECH anode.
1 «This regulation applies in France and the installer must keep up to date with all subsequent modifications. For installation
in other countries, please refer to applicable local regulations.».
Recommendation when installing in the bathroom:
The water heater installation in the bathroom must
be adapted in accordance with national rules and
standards in force (NFC 15-100, RGIE, etc.).
Volume classifications:
Volume 0: This is the interior volume of the
bathtub or shower tray.
Volume 1: This is the volume outside that
bathtub or shower tray and is limited on the one
side by the vertical cylindrical surface circumscri-
bed to the edge of the bathtub or shower tray, and
on the other by the horizontal plane at 2.25 m from
the bottom of the bath or shower base.
Volume 2: This is the volume external to
volume 1. It is limited by the vertical cylindrical
surface 0.60m from the edge of the bathtub or
shower tray and limited by a horizontal plane at
2.25 m above the bottom of the bathtub or shower
tray.
Volume 3: This is the volume external to
volume 2. It is limited by the vertical cylindrical
surface 2.40m from volume 2 and limited by a
horizontal plane at 2.25 m above the bottom of the
bathtub or shower tray.
Authorised water heater fixing zones:
Fixed, low voltage water heaters are permitted in
volume 1 as long as they have maximum protec-
tion level (IPX4). Please note: horizontal type water
heaters, installed as high up as possible in volume
1 are permitted for France only.
4. If the appliance is installed in a room which
is just above an inhabited space (a loft, attic,
false ceiling, etc.), insulate the piping and fit a
retention tank with water drainage. Connection
A* models only HPC
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston PROfessional TECH-serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston PROfessional TECH-serie in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info