719601
24
Zoom out
Zoom in
Previous page
1/208
Next page
IT
24 /
CARATTERISTICHE TECNICHE PER INSTALLAZIONI MONOSPLIT
MODELLO UNITA’ ESTERNA
PRIOS R32 25 MD0-O PRIOS R32 35 MD0-O PRIOS R32 50 MD0-O PRIOS R32 70 MD0-O
Diametro tubo del liquido
pollici 1/4 1/4 1/4 3/8
Diametro tubo del gas
pollici 3/8 3/8 1/2 5/8
Massima lunghezza del tubo con
carica standard
m5 5 5 5
Massima lunghezza del tubo*
m25 25 30 50
Carica standard
kg 0,5 0,5 1 1,6
t CO eq.
0,34 0,34 0,68 1,08
Carica supplementare del gas
g/m 12 12 12 12
Massimo dislivello tra unità interna
ed esterna**
m10 10 20 25
Tipo di refrigerante
R32 R32 R32 R32
GWP
675 675 675 675
CARATTERISTICHE TECNICHE PER INSTALLAZIONI MULTISPLIT
MODELLO UNITA’ ESTERNA
DUAL 50
XD0C-O
TRIAL 80
XD0C-O
QUAD 110
XD0C-O
PENTA 121
XD0C-O
Diametro tubo del liquido pollici 2x 1/4 3x 1/4 4x 1/4 5x 1/4
Diametro tubo del gas pollici 2x 3/8 3x 3/8 3x 3/8+ 1x1/2 4x 3/8 + 1x 1/2
Massima lunghezza del tubo per singola unità interna
con carica standard
m
555 5
Massima lunghezza del tubo per singola unità interna* m 25 30 35 35
Lunghezza totale massima delle tubazioni
(somma unità interne)*
m
40 60 80 80
Carica standard
kg
1,3 1,57 2,1 2,4
t CO eq. 0,88 1,06 1,42 1,62
Carica supplementare del gas g/m 15 15 15 15
Massimo dislivello tra unità interna ed esterna
(unità interna al di sopra dell’unità esterna) **
m
15 15 15 15
Massimo dislivello tra unità interna ed esterna
(unità interna al di sotto dell’unità esterna) **
m
10 10 10 10
Massimo dislivello tra le unità interne m 10 10 10 10
Tipo di refrigerante R32 R32 R32 R32
GWP 675 675 675 675
(*) alla distanza massima il rendimento è di circa il 90%.
(**) con dislivello superiore a 5 m è consigliato prevedere un sifone.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Prios R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Prios R32 in the language / languages: English, Dutch, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 4,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info