Installation Instructions for built-in
The following instructions are directed at the qualified
installer so that the installation and maintenance
proceedures may be followed in the most professional and
expert manner possible. Important: Unplug the electrical
connection before performing any maintenance or
regulation upkeep work.
Positioning for gas hob
Important: this unit may be installed and used only in
permanently ventilated rooms according to the British
Stancards Codes Of Practice: B.S. 6172 / B.S. 5440, Par.
2 and B.S. 6891 Current Editions. The following
requirements must be observed:
a) The room must be fitted with a ventilation system which
vents smoke and gases from combustion to the outside.
This must be done by means of a hood or electric
ventilator that turns on automatically each time the hood
is operated.
In a chimney stack or branched flue. Directly to the Outside
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed
for proper combustion. The flow of air for combustion
purposes must not be less than 2 m
3
/h per kW of installed
capacity. The supply of said air can be effected by means
of direct influx from the outside through a duct with a
inner cross section of at least 100 cm² which must not be
able to be accidentally blocked. Those appliances which
are not fitted with a safety device to prevent the flame
from accidentally going out must have a ventilation
opening twice the size otherwise required, i.e. a minimum
of 200cm
2
(Fig. A). Otherwise, the room can be vented
indirectly through adjacent rooms fitted with ventilation
ducts to the outside as described above, as long as the
adjacent rooms are not shared areas, bedrooms or
present the risk of fire (Fig. B).
Detail A Adjacent Room to be
Room Vented
A
Examples of ventilation holes Enlarging the ventilation slot
for comburant air. between window and floor.
Fig. A Fig. B
c) Intensive and prolonged use of the appliance may ne-
cessitate supplemental ventilation, e.g. opening a window
or increasing the power of the air intake system (if present).
d) Liquidified petroleum gases are heavier than air and, as
a result, settle downwards. Rooms in which LPG tanks
are installed must be fitted with ventilation openings to
the outside in order to allow the gas to escape in the
event of a leak. Therefore, LPG tanks, whether empty or
partially full, must not be installed or stored in rooms or
spaces below ground level (cellars, ect.). It is also a good
idea to keep only the tank currently being used in the
room, making sure that it is not near sources of heat
(ovens, fireplaces, stoves, etc.) that could raise the internal
temperature of the tank above 50°C.
Installation of built-in stove tops
The appliance can be installed next to furniture units which
are no taller than the top of the cooker hob. The wall in
direct contact with the back panel of the cooker must be
made of non-flammable material. During operation the
back panel of the cooker could reach a temperature of
50°C above room temperature. For proper installation of
the cooker, the following precautions must be taken:
a) The hob may be located in a kitchen, a kitonen/diner
or bed sitting room, but not in a bathroom or shower
room.
b) The furniture standing next to the unit, that is higher
than the working boards, must be placed at least
110mm from the edge of the board.
c) The cabinets should be positioned next to the hood at
a height of at least 420 mm (Fig. C).
600mm min.
540mm min.
700mm min.
Fig. C
d) Should the hob be installed directly under a cupboard,
the letter should be at least 700mm (millimetres) from
the worktop, as shown in Fig. C.
e) The dimensions of the room for the furniture must be
those indicated in the figures in the last two pages of
the cover. Fixing hooks are provided which allow to
place the hob plate on work tops that measure from
20 to 40 mm in thickness (see Fig. D). To obtain a good
fixing of the hob plate it is advisable to use all the hooks
supplied.
475 mm.
835 mm.
min. 55 mm.
Fig. D
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston PH 960 MST GH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston PH 960 MST GH in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info