Worked Example
The example below is for a G½ 6 with a discharge pipe
(D2) having 4 No. 22mm elbows and length of 7m from
the tundish to the point of discharge.
From Table 1:
Maximum resistance allowed for a straight length of
22mm copper discharge pipe (D2) from a G½
temperature relief valve is: 9.0m
Subtract the resistance for 4 No. 22mm elbows at 0.8m
each = 3.2m
Therefore the maximum permitted length equates to:
5.8m which is less than the actual length of 7m therefore
calculate the next largest size.
Maximum resistance allowed for a straight length of
28mm copper discharge pipe (D2) from a G½
temperature relief valve is: 18m
Subtract the resistance for 4 No. 28mm elbows at 1.0m
each = 4m
Therefore the maximum permitted length equates to:
14m
As the actual length is 7m, a 28mm (D2) copper pipe
will be satisfactory.
FIG. 6.16A TYPICAL EXPANSION DISCHARGE ARRANGEMENT
6.16 NUOS EXPANSION DISCHARGE
3.58Where a single common discharge pipe serves
more than one system, it should be at least one pipe
size larger than the largest individual discharge pipe (D2)
to be connected.
3.59The discharge pipe should not be connected to a
soil discharge stack unless it can be demonstrated that
the soil discharge stack is capable of safely withstanding
temperatures of the water discharged, in which case, it
should:
a. contain a mechanical seal, not incorporating a water
trap, which allows water into the branch pipe without
allowing foul air from the drain to be ventilated
through the tundish;
b. be a separate branch pipe with no sanitary
appliances connected to it;
c. if plastic pipes are used as branch pipes carrying
discharge from a safety device they should be either
polybutalene (PB) to Class S of BS 7291-2:2006 or
cross linked polyethylene (PE-X) to Class S of BS
7291-3:2006; and
d. be continuously marked with a warning that no
sanitary appliances should be connected to the
pipe.
Not to scale
Cold
Feed
Expansion
Vessel
NUOS Temperature and
Pressure Relief Valve (TPRV)
15mm
15mm
Pressure Relief
Valve (PRV)
Balanced
Cold Supply
to Taps
Hot
Supply
to Taps
Tundish
Condensate Drain
Connect to appliance using
½ elbow spigot supplied.
33


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-nuos-plus

Reset search

  • Pas d’eau chaude
    Marqué boost dans l’appareillante Submitted on 12-11-2021 at 22:31

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS PLUS in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston NUOS PLUS

Ariston NUOS PLUS User Manual - German - 33 pages

Ariston NUOS PLUS User Manual - Dutch - 35 pages

Ariston NUOS PLUS User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info