1.6 BASIC PRINCIPLES OF A
HEAT PUMP
FIG. 1.6A BASIC PRINCIPLES
Within the heat pump the refrigerant is warmed from its cooled state to
the ambient or external air temperature. This heat gain is largely free
energy.
Electricity is used to power the fan which draws air, and also the compressor
which pressurises the refrigerant to increase it’s heat. A small amount of
electricity is also required to run the heat pump’s control system.
The efficiency of a heat pump cycle is stated by its Coefficient of
Performance (COP) value. This is a ratio between the energy produced
by the heat pump to the electrical energy supplied to it. For example a
COP of 3.0 indicates that for every 1kW of electricity used the heat pump
will produce 3.0 kW of hot water, therefore giving 2.0kW of free energy.
1.7 EFFICIENCY
FAN
The fan draws air through
the heat exchanger.
The cool refrigerant is
heated by the ambient or
external air temperature.
The refrigerant boils and
turns to vapour.
The compressor increases the
pressure of the refrigerant
vapour causing it to
significantly increase in
temperature
Heat from the hot
pressurised refrigerant
vapour is transferred to the
water in the stored water
vessel by a second heat
exchanger called a
condenser.
As the refrigerant is cooled
it reverts back to its liquid
state.
The refrigerant liquid
passes through a pressure
reducing valve (changing
from small bore to larger
bore pipe).
The reduction of pressure
significantly cools the
refrigerant fluid.
HEAT
EXCHANGER
(Evaporator)
COMPRESSOR
1
2
3
STORED WATER
VESSEL
CONDENSER
PRESSURE
REDUCING VALVE
(EXPANSION VALVE)
4
To hot water taps
AMBIENT or
EXTERNAL
AIR
HIGH PRESSURE
REFRIGERANT IN
SEALED SYSTEM
Cold Feed
6


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-nuos-plus

Reset search

  • Pas d’eau chaude
    Marqué boost dans l’appareillante Submitted on 12-11-2021 at 22:31

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS PLUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS PLUS in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston NUOS PLUS

Ariston NUOS PLUS User Manual - German - 33 pages

Ariston NUOS PLUS User Manual - Dutch - 35 pages

Ariston NUOS PLUS User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info