ECONOMY/COMFOR
T MODE
The selector knob “E” allows the user to choose the economy mode (position “E”) or the
comfort mode (position “C”).
The economy mode is the normal state for the operation of the boiler, since the domestic
water is heated up only when a tap is turned on.
The comfort mode is a special operating state, because the water contained in the
secondar
y exchanger and in the primary exchanger is kept in a pre-heated condition,
thereby allowing a quicker delivery of Domestic Hot Water when required.
TURNING OFF THE CENTRAL HEATING
To turn off the Central Heating, rotate the “C” knob to the “0” position.
The boiler will sta
y in ‘summer’ mode, providing Domestic Hot Water on request.
TURNING
OFF THE BOILER
To turn the boiler off, rotate the selector knob “A” to the “0” position (OFF); the display
will go off
. Close the gas cock located under the boiler and turn the electricity supply
s
witch (located outside the boiler) to the OFF position.
BOILER SHUTDOWN SITUATIONS
The boiler is equipped with safety devices that intervene in certain situations and shut it
off. Most of these situations are signalled by means of the L.E.D.s and in some
circumstances the user may be able to remedy them.
SHUTDOWN DUE TO IGNITION FAILURE
This anomaly is indicated by
AA 0011
on the display. To reset the boiler, press
and then release the
“D” button.
At this point, the electronic ignition system will attempt to light the burner again.
Should the boiler fail to ignite a second time, check that the external gas
cock is open. If the problem persists, contact an Authorised Service
Centre.
SHUTDOWN DUE TO OVERHEATING
This anomaly is indicated b
y
AA 0033
on the displa
y
.
The boiler has shutdo
wn
because the safety thermostat detected that the boiler temperature has
exceeded the maximum limit.
T
o reset this state, wait until the boiler has cooled and press the button
“D”.
If the safety thermostat operates on a frequent basis, contact one of our
Authorised Service Centres.
SHUTDOWN DUE TO INSUFFICIENT WATER CIRCULATION
This anomaly is indicated b
y
EE 0022
on the displa
y.
One of the possible causes of this shutdown situation could be the lack of water
in the boiler or water circulation failure in the primary heating circuit.
Check the system pressure on the pressure gauge
“K” and, if it is less than 0.5
bar, try bringing the system pressure up to a mean value
of 1.0 bar by opening the water inlet valve. Then reset by
turning the boiler off and then back on by pressing the
button “D”.
3.USEFUL INFORMATION
AND TROUBLESHOOTING
E
C
E
C
E
econom
y
EC EC
conf
ort
PL006D
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
II II
PL004D
C
PL008D
A
PL007D
PL055D
PL012D
K
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston MicroGenus HE 32 MFFI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston MicroGenus HE 32 MFFI in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info