INSTALLING NORMS (for the installer)
This product, excluding horizontal models (Table 1), is a device that must be installed vertically in order to oper-
ate correctly. Once installation is complete, and before any water is added or the power supply is connected,
use a measuring instrument (i.e. a spirit level) to check that the device has been installed perfectly vertical. The
appliance heats water to a temperature below boiling point. It must be linked up to a mains water supply according to
the appliance performance levels and capacity. Before connecting the appliance, it is  rst necessary to:
- Check whether the characteristics (please refer to the data plate) meet the customers requirements.
- Make sure the installation conforms to the IP degree (of protection against the penetration of liquids) of the appli-
ance according to the applicable norms in force.
- Read the instructions provided on the packaging label and on the appliance data plate.
This appliance was designed to be installed only inside buildings in compliance with the applicable norms in force.
Furthermore, installers are requested to keep to the following advice in the presence of:
- Damp: do not install the appliance in closed (unventilated) and damp rooms.
- Frost: do not install the appliance in areas where the temperature may drop critically and there may be a risk that ice
may form.
- Sunlight: do not expose the appliance to direct sunrays, even in the presence of windows.
- Dust/vapours/gas: do not install the appliance in the presence of particularly dangerous substances such as acidic
vapours, dust or those saturated with gas.
- Electrical discharges: do not install the appliance directly on electrical supplies that aren’t protected against sud-
den voltage jumps.
In the case of walls made of bricks or perforated blocks, partition walls featuring limited static, or masonry di erent in
some way from those stated, you  rst need to carry out a preliminary static check of the supporting system.
The wall-mounting fastening hooks must be designed to support a weight that is three times higher than the weight
of the water heater  lled with water.
Fastening hooks with a diameter of at least 12 mm are recommended.
We recommend installing the appliance (A Fig. 1) as close as possible to the delivery points to minimise heat loss along
the pipes. Local regulations may provide for restrictions on installation in bathrooms; observe any regulatory minimum
distances. To facilitate maintenance, make sure there is a clearance of at least 50 cm inside the enclosure for access to
the electrical equipment.
Hydraulic connection
Connect the water heater’s inlet and outlet with pipes or  ttings that are able to withstand temperature in excees of
90°C at a pressure exceeding that of the working pressure. Therefore, we advise against the use of any materials which
cannot resist such high temperatures.
The appliance must not be supplied with water of hardness less than 12°F, nor with especially hard water (greater than
25°F); we recommend installing a water softener, properly calibrated and controlled - do not allow the residual hard-
ness to fall below 15°F.
Screw a “T piece union to the water inlet pipe with the blue collar. On one side of the T piece union, screw a tap for
draining the appliance that can only be opened with the use of a tool (B Fig. 2). On the other side of the “T piece union
screw the safety valve supplied (A Fig. 2).
Safety group complies with the European standard EN 1487
Some countries may require the use of hydraulic special safety devices; the installer must check the suitability of the
safety device he tends to use.
Do not install any shut-off device (valve, cock, etc.) between the safety unit and the heater itself.
The appliance's drain outlet must be connected to a drain pipe of diameter at least equal to the of the outlet itself, with
a funnel to permit an air gap of at least 20 mm for visual inspection. Use a hose to connect the safety group to the mains
cold water supply;  t a cock if necessary (D g. 2). In addition, a water discharge tube on the outlet C Fig. 2 is necessary
if the emptying tap is opened.
When installing the safety device, do not tighten it fully down, and do not tamper with its settings.
It is necessary to connect the drain, which must always be left exposed to the atmosphere, with a drainage pipe that is
installed sloping downwards in a place with no ice. If the network pressure is closed to the calibrated valve pressure, it
will be necessary to apply a pressure reducer far away from the appliance. To avoid any possible damage to the mixer
units (taps or shower) it is necessary to drain any impurities from the pipes.
16


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-lydos-eco-eu

Reset search

  • where is the cold water valve on the Ariston Lydos Eco Blue model? my unit is unplugged and has a slow drip and I cant purge the tank to stop it from dripping
    Submitted on 18-12-2023 at 09:51

    Reply Report abuse
  • My ariston water heater is set to 80 but is not producing hot water Submitted on 19-5-2022 at 15:08

    Reply Report abuse
  • The heater has a thermostat. If the thermostat is set at 80 Centigrade and there is a power cut does the temperature setting remain at 80 when power is restored ? Submitted on 29-1-2022 at 17:10

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Lydos Eco EU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Lydos Eco EU in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info