454972
27
Zoom out
Zoom in
Previous page
1/58
Next page
28
Electrical connections
Voltage,
Frequency
Fuses,
Sections
FR-AT-BE-DE-GP--
ES-IE-IL-IS-IT-LU-
RE-FI-GB-GR-PT--
SE-MA-NZ
230V-1+N~50 Hz
25 A*
2,5 mm²
FR-BE-NO
230V-2~50/60 Hz
25 A*
2,5 mm²
FR-BE-CH-DE-AT--
ES-IL-IT-NZ-PT-
MA- LU-SE-IS-NL
400V2-N~50 Hz
16 A*
1,5 mm²
FR-BE-NO
230V3~50 Hz
16 A*
1,5 mm²
FR-AT-BE-DE-ES-
IL-IS-IT-LU-PT-SE
-MA-NZ-CH-DK-N-
L
400V3+N~50 Hz
16 A*
1,5 mm²
NL
230V2+2-N~50 Hz
16 A*
1,5 mm²
CY-AU-NZ-KW-MT
240V-1+N~50 Hz
25 A*
2,5 mm²
* Application of the simultaneity coefficient in accordance with
cei 60335-2-6 norm
Technical characteristics
This appliance conforms with the following European
Community Directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89 (Electromagnetic
compatibility) and subsequent amendments;
- 93/68/EEC of 22/07/93 and subsequent amendments;
Warning: If the hob is fitted above a built-in oven, the hob
and the oven must be connected to the mains separately for
safety reasons and to simplify operations when it is necessary
to pull the oven out for some reason.
Electrical connection
The electrical safety of this appliance can only be
guaranteed if the latter is correctly and efficiently
earthed, in compliance with regulations on electrical
safety. Always ensure that this vital safety measure has
been taken. If you have any doubts, call in a qualified
technician to check the electrical system thoroughly.
The manufacturer denies all responsibility for
damage resulting from a system which has not been
earthed correctly.
Before powering the appliance, check whether the
technical characteristics featured on the appliance data
plate correspond with those of the mains electrical
system.
Check that the current load of the mains supply and
of the power sockets is suitable for the maximum power
of the appliance, indicated on the appliance data plate.
If in doubt, contact a qualified professional.
Disconnect the appliance from the electricity supply
before all operations.
Connect your hob to the electrical system by means of a
junction box: if the appliance is connected permanently
to the mains, an omnipolar circuit breaker, accessible if
necessary, with a minimum contact opening of 3 mm
should be installed.
Valid only for models with a power supply cable
Some models are supplied with a single-phase power
supply cable, and should consequently only be connected
to the single-phase mains. Observe the wire colours, as
indicated in the diagram attached.
Electrical connections Voltage, Frequency Fuses, Sections
FR-BE-AT-DE-GR-ES-IL-
IT-NZ-PT-GP-CH-MA-LU-
IE-FI-SE-IS-GB-NL-DK
230V - 1+N~ 50Hz
CY-MT-AU-NZ-KW
240V - 1+N~ 50Hz
25A *
2,5 mm²
FR-BE-NO
230V - 2 ~ 50Hz
BR=BRUN,BL=BLEU
BR=BRUIN, BL=BLAUW
BR=BRAUN, BL=BLAU
BR=BROWN, BL=BLUE
* Application of the simultaneity coefficient in accordance with
cei 60335-2-6 norm
Valid only for models without a power supply
cable
Some models are not fitted with a power supply cable, as
the cable should be sized according to the type of electrical
connection in use (see connection table below). To connect
the cable, proceed as follows:
Using a screwdriver, prise on the side tabs of the
terminal board cover;
Pull open the cover of the terminal board.
LN
12345
L1 L2
12345
L1 L2 N
12345
L1 L2 L3
12345
L1 L2 L3 N
12345
L1 L2 N2N1
12 34 5
LN
12345
To install the cable, proceed as follows:
unscrew the wire clamp screw and the contact screws.
to make the desired electrical connection (see table),
use the jumpers housed inside the box. Position the
power supply cable wires according to the indications
in the table.
once the connections have been made, tighten all the
terminal screws fully.
Fasten the supply cable in place with the clamp and
close the cover of the terminal board.
BL
N
BR
L
BL
N
BR
L
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston KBT 6001 H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston KBT 6001 H in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info