SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
menu
sub-menu
Parameter
Description value
default setting
2 7 1 Bleed cycle press OK button for 5 seconds see First Ignition parag.
2 8 RESET MENU’ 2
2 8 0 Automatically resetting to the default setting
in menu 2
Reset
OK = yes
ESC = no
To reset all default parameter
settings, press the OK button
4 ZONE 1 PARAMETER
4 0 ZONE 1 TEMPERATURE SETTING
4 0 2 Heating xed temperature setting
“Heating xed temp”
from 35 to 82 °C
(high temperature - para. 420
=1)
70 Activated only with temperature
control and xed temperature
(see 421)
from 20 to 45 °C
(high temperature - para. 420
=0)
20
4 2 ZONE 1 SETTING
4 2 0 Heating appliance temperature value setting 0 = from 20 to 45°C
(low temperature)
1 = from 35 to 85°C
(high temperature)
select in the appliance type
base
4 2 1 Basic heating control type selection type
depending on the peripheral devices
connected
0 = xed ow temperature
1 = device On/Off
2 = room sensor
3 = external sensor only
4 = room sensor +
external sensor
1 To activate heating control,
press the AUTO button. The
display lights up the AUTO
symbol
4 2 2 Slope from 0_2 to 0_8 (low temperature)
from 1_0 to 3_5 1_5 (high temperature)
Flow Temperature
Low temperature High temperature
External temperature
Ambiente temperature
setting value
°C
20
25
15
30
40
50
60
70
80
90
100 °C
10
2.5 3.0 3.5 2.0
1.5
1.2
1.0
0.8
0.6
0.4
0.2
5 0 -5 -10 -15 -20 °C
If the external sensor is used,
the boiler calculates the
most suitable heating ow
temperature taking the external
temperature and the type of
appliance into account.
The type of curve must be
chosen according to the type of
appliance radiator and the heat
losses present in the building.
4 2 3 Parallel shift from - 7 to + 7 (low temperature) 0
from - 14 to + 14
(high temperature)
To adapt the thermal curve to the appliance requirements, it is possible to perform
a parallel shift of the curve in order to alter the calculated ow temperature and
therefore the ambient temperature.
By accessing this parameter or pressing the buttons 8 the curve can be shifted in a
parallel manner as indicated in the gure shown below.
The value is indicated on the display:
- from -7 to +7
(low temperature)
- from -14 to +14
(high temperature)
Each step represents a ow temperature increase/decrease of 1°C in relation to the
set-point value.
43


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-e-combi-one

Reset search

  • Is this the manual for the new Ariston E combi One 24 kw LPG Boiler that does not have a pressure gauge on the front panel ? Submitted on 11-8-2023 at 10:49

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-Combi One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-Combi One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-Combi One

Ariston E-Combi One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info