COMMISSIONING
ON
OFF
1
2
5
6
l
FR
Dans le cas d’une dureté de l’eau
supérieure à 20 °f, prévoir un traitement de
’eau.
NL
Bij waterhardheid van meer dan 20
°f, een waterverzachter voorzien.
DE
Wenn
der Härtegrad des Wasser über 11°dH (20 °f)
beträgt, ist eine Wasserenthärtung
vorzusehe
n.
IT
Se l’acqua ha una durezza
superiore a 20 °f, prevedere un dispositivo di
trattamento.
ES
En el caso de que la dureza
del agua sea superior a 20 °f, prever un
tratamiento del agua.
PT
Nos casos em que a
dureza da água seja superior a 20 °f, prever
um sistema de tratamento de água.
UK
If the
water hardness is more than 20 °f, install a
water softener.
CZ
V prípade, ze tvrdost vody
presahuje 20 °f, je treba aplikovat vhodnou
úpravnu vody.
HU
Ha a víz keménysége
nagyobb, mint 20°f német keménységi fok,
akkor a víz kezelésér l gondoskodni
kell.
PL
twar
wody jest w
nale
y zainstal
ow
owiednie ur
zenie.
TR
20 °f su sertli
ini geçen sular için su
ar
ıtma tavsiye edilmelidir (su arıtma
teriye aittir).
RO
Daca apa are o duritate
ma
i m
are dacat 20 °f, este necesara tratarea in
ea
labi
l a acesteia.
RU
.
XXXX
xxxxx
xxxxx
xxx
XXXX
xxx
MIN
Q
MAX
P
60/80°C
G30 - G31 28/37 mbar
1009942-05
5
4
2
1
3
Converting the appliance from Natural gas to LPG
These appliances are designed to operate with different gas
types.
The appliance must only be converted for use with a different
gas type by a Gas Safe Registered installer.
To convert the appliance to LPG:
(use these instructions in conjunction with the Instruction sheet
supplied with the LPG Kit).
1.
Electrically isolate the appliance (g 1)
2. Turn off the gas supply (g 2)
3. Remove the outer case, lower the
front control panel.
4. Remove the silencer (g 3)
5. Disconnect the gas supply from
the venturi assembly (g 4)
6. Inset the correct diaphragm
(depending on the output of the
appliance) into the venturi spigot
(g 5)
7. Reassemble the gas supply onto the venture assembly (g 4)
and reattach the silencer.
8. Turn on gas supply and test for tightness
9. Purge gas supply
10. Turn the electrical supply on to the appliance.
11. Commission the appliance, check the working pressure is
adequate then test and adjust the CO² values at maximum
and minimum output described in the commissioning section
of the appliance installation instructions. Ensure the ue
gas analyser used is calibrated and set for the gas group
the appliance is being
adjusted for.
12. Check the appliance
for gas leaks using
gas leak detection
uid.
13. Afx the label to
the appliance that
is supplied with the
conversion kit.
AUTO function
This is a function which enables the boiler to automatically
adapt its operation routine (the temperature of the heating
elements) in line with the outdoor conditions, in order to achieve
and maintain the requested room temperature conditions.
Depending on the peripheral units connected and the number
of zones controlled, the boiler adjusts its ow temperature
automatically.
The various
corresponding
parameters should
therefore be set (see
adjustments menu).
To activate the function,
press the
auto button.
Example 1:
Single zone system (high-temperature) with on/off room
Thermostat:
In this case the following parameters must be set:
4 21 - Activation of temperature adjustment using sensors
- Select 1 = Basic temperature adjustment
2 44 - Boost Time (optional)
The wait time for the ow temperature increase in steps of
4°C may be set. The value varies according to the type of
system and installation.
If the Boost Time value = 00 the function is not activated.
Example 2:
Single zone system (high-temperature) with on/off room
Thermostat + outdoor sensor:
In this case the following parameters must be set:
4 21 - Activation of temperature adjustment using sensors
- Select 3 = outdoor sensor only
4 22 - Temperature adjustment curve selection
- Select the relevant curve according to the type of
system, installation, heat insulation used in the building,
etc.
4 23 - Perform a parallel curve shift if necessary, increasing
or decreasing the set-point temperature (this may also
be modied by the user, using the heating temperature
adjustment knob, which, with the Auto function activated,
is used to shift the curve in a parallel manner).
Example 3:
Single zone system (high-temperature) with Sensys controller +
outdoor sensor
In this case the following parameters must be set:
4 21 - Activation of temperature adjustment using sensors
- select 4 = outdoor sensor + room sensor
4 22 - Temperature adjustment curve selection
- Select the relevant curve according to the type of
system, installation, heat insulation used in the building,
etc
4 23 - Perform a parallel curve shift if necessary, increasing or
decreasing the set-point temperature. (This may also be
changed by the user by the buttons 8 which, with the
Auto function activated, is used to shift the curve in a
parallel manner.)
4 24 - Inuence of room sensor
- used to adjust the inuence the room temperature has
on the calculation of the set-point ow temperature (20 =
maximum, 0 = minimum).
Note: See page 40 for details on accessing menus.
37


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-e-combi-one

Reset search

  • Is this the manual for the new Ariston E combi One 24 kw LPG Boiler that does not have a pressure gauge on the front panel ? Submitted on 11-8-2023 at 10:49

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston E-Combi One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston E-Combi One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston E-Combi One

Ariston E-Combi One User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info