507045
24
Zoom out
Zoom in
Previous page
1/72
Next page
24
GB
Installation
! Before placing your new appliance into operation please
read these operating instructions carefully. It contains
important information concerning the safe installation and
operation of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with the
appliance if it is sold, given away or moved.
! The appliance must be installed by a qualied professional
in accordance with the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected from
the electricity supply.
Room ventilation
The appliance may only be installed in permanently-
ventilated rooms, according to current national legislation.
The room in which the appliance is installed must be
ventilated adequately in order to provide as much air as is
needed by the normal gas combustion process (the ow of
air must not be lower than 2 m
3
/h per kW of installed power).
The air inlets, protected by grilles, should have a duct
with an inner cross section of at least 100 cm
2
and should
be positioned so that they are not liable to even partial
obstruction (see gure A).
These inlets should be enlarged by 100% - with a minimum of
200 cm
2
- whenever the surface of the hob is not equipped with
a ame failure safety device. When the ow of air is provided in
an indirect manner from adjacent rooms (see gure B), provided
that these are not communal parts of a building, areas with
increased re hazards or bedrooms, the inlets should be tted
with a ventilation duct leading outside as described above.
A
Examples of
ventilation holes
for comburant air.
Enlarging the ventilation slot
between window and floor.
Adjacent
Room
Room to be
Vented
A B
! After prolonged use of the appliance, it is advisable to open
a window or increase the speed of any fans used.
Disposing of combustion fumes
The efcient disposal of combustion fumes should be
guaranteed using a hood which is connected to a safe
and efcient natural suction chimney, or using an electric
fan which begins to operate automatically every time the
appliance is switched on (see gure).
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the Outside
! The liqueed petroleum gases are heavier than air and
collect by the oor, therefore all rooms containing LPG
cylinders must have openings leading outside so that any
leaked gas can escape easily.
LPG cylinders, therefore, whether partially or completely full,
must not be installed or stored in rooms or storage areas which
are below ground level (cellars, etc.). Only the cylinder being
used should be stored in the room; this should also be kept well
away from sources of heat (ovens, chimneys, stoves) which
may cause the temperature of the cylinder to rise above 50°C.
Positioning and levelling
! The appliance may be installed alongside any cupboards
whose height does not exceed that of the hob surface.
! Make sure that the wall in contact with the back of the appliance
is made from a non-ammable, heat-resistant material (T 90°C).
To install the appliance correctly:
Place it in the kitchen, the dining room or the studio at
(not in the bathroom).
If the top of the hob is higher than the cupboards, the
appliance must be installed at least 500 mm away from
them.
HOOD
420
Min.
min. 650 mm. with hood
min.
700 mm. without hood
mm.
600
Min. mm.
420
Min. mm.
If the cooker is installed
underneath a wall cabinet, there
must be a minimum distance of 420
mm between this cabinet and the
top of the hob.
This distance should be increased
to 700 mm if the wall cabinets are
ammable (see gure).
Do not position blinds behind the cooker or less than 200
mm away from its sides.
Any hoods must be installed in accordance with the
instructions listed in the relevant operating manual.
Levelling
If it is necessary to level the
appliance, screw the adjustable
feet into the places provided on
each corner of the base of the
cooker (see gure).
Electrical connection
Install a standardised plug corresponding to the load indicated
on the appliance data plate (see Technical data table).
The appliance must be directly connected to the mains using
an omnipolar switch with a minimum contact opening of 3
mm installed between the appliance and the mains. The
switch must be suitable for the charge indicated and must
comply with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply cable
must be positioned so that it does not come into contact
with temperatures higher than 50°C at any point.
Before connecting the appliance to the power supply, make
sure that:
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston CP 059 MD.3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston CP 059 MD.3 in the language / languages: English, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 23,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info