COMP
FM1
MAIN BOARD
RED
BLACK
U
V
W
Y/G
Y/G
L
L-PRO
T3
T4
H-PRO
Y/G
TP
V
U
C N 1 9
C N 5 1
C N 5 5
W
F AN1
~
BLACK
DRIVER BOARD
RED
7
7
YELLOW
BLUE
P-1
Applicable to the units
adopting DC motor only
Applicable to the units
adopting AC motor only
CAP1
C N 5 3
C N 4 1
C N 4 3
C N 3
C N 4
C N 1 0
C N 4 0
C N 2 2
C N 4 2
C N 4 4
C N 8
C N 9
C N 7
C N 2
C N 1
C N 5
C N 5 4
C N 5 2
3
C N 3 3
C N 6
5
BLACK
BLACK
SV
4- W AY1
OPTIONAL
NOTE:Four-way valve
is used in the
Cooling & Heating
unit only
BLUE
BLUE
HEA T_D
HEA T_Y
OPTIONAL
3
BLACK
RED
BLUE
BLUE
BLUE
YELLOW
RED
BLACK
RED
BLACK
EEV
C N 2 0
M
5 (6 )
A
C N 2 1
M
5 (6 )
B
C N 1 7
M
5 (6 )
C
C N 1 9
M
5 (6 )
E
C N 1 8
M
5 (6 )
D
C N 2 9
C N 2 8
C N 2
7
C N 2 6
T2B-A B C D E
CN13
INDOOR
PIPE OUT
TEMP A B C D E
L(C)
N(C)
S(C) L(D)
N(D)
S(D) L(E) N(E)
S(E)
NWORB
NWORB
EULB
EULB
KCALB
KCALB
CODE P ART NAME
COMPRESSOR
HEA T
4-W AY V AL VE
COMP
CAP1
EEV
ELECTRIC EXP ANSIVE
VAL VE
OUTDOOR AC F AN
F AN1
H-PRO
L-PRO
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
T3
T4
CONDENSER
TEMPERA TURE SENSOR
OUTDOOR AMBIENT
TEMPERA TURE SENSOR
CRANKCASE HEA TING
SV
L
PFC INDUCT OR
TH
HEA TSINK
TEMPERA TURE SENSOR
TP
EXHAUST
TEMPERA TURE SENSOR
FM1
OUTDOOR DC F AN
F AN MOT OR CAP ACIT OR
P ART NAMECODE
BLUE
BLUE
RDE
BLACK
BLACK
RDE
C N 3 0
POWER
SUPPLY
L
N
L(B)
N(B)
S(B)
L(A)
N(A)
S(A)
NWORB
EULB
KCALB
NWORB
EULB
KCALB
NWORB
EULB
KCALB
C N 1 6
Y/G
TO B
Y/G
TO C
Y/G
TO E
Y/G
TO A
Y/G
TO D
DR BOARD
CN1
4
RJ45
FOR USER
TO CONNECT
OPTIONAL
CN5
OPTIONAL
RED
BLUE
CN2
OLP TEMP . SENSOR
C N 1 4
OPTIONAL:
TOP TEMPERATURE
PROTECTION OF
COMPRESSOR
Notes:
This symbol indicates the element
is optional,the actual shape
shall be prevail.
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
PENTA 121 XD0C-O
COMP
FM1
MAIN BOARD
U
V
W
Y/G
Y/G
L
L-PRO
T3
T4
H-PRO
Y/G
TP
V
U
C N 1 9
C N 5 1
C N 5 5
W
F AN1
~
BLACK
DRIVER BOARD
RED
7
7
YELLOW
BLUE
P-1
Applicable to the units
adopting DC motor only
Applicable to the units
adopting AC motor only
CAP1
C N 5 3
C N 4 1
C N 4 3
C N 3
C N 4
C N 1 0
C N 4 0
C N 2 2
C N 4 2
C N 4 4
C N 8
C N 9
C N 7
C N 2
C N 1
C N 5
C N 5 4
C N 5 2
3
C N 3 3
C N 6
5
BLACK
BLACK
SV
4- W AY1
OPTIONAL
NOTE:Four-way valve
is used in the
Cooling & Heating
unit only
BLUE
BLUE
HEA T_D
HEA T_Y
OPTIONAL
3
BLACK
RED
BLUE
BLUE
BLUE
YELLOW
RED
BLACK
RED
BLACK
EEV
C N 2 0
M
5 (6 )
A
C N 2 1
M
5 (6 )
B
C N 1 7
M
5 (6 )
C
C N 1 9
M
5 (6 )
E
C N 1 8
M
5 (6 )
D
C N 2 9
C N 2 8
C N 2 7
T2B-A B C D E
CN13
INDOOR
PIPE OUT
TEMP A B C D E
CODE P ART NAME
COMPRESSOR
HEA T
4-W AY V AL VE
COMP
CAP1
EEV
ELECTRIC EXP ANSIVE
VAL VE
OUTDOOR AC F AN
F AN1
H-PRO
L-PRO
LOW PRESSURE SWITCH
HIGH PRESSURE SWITCH
T3
T4
CONDENSER
TEMPERA TURE SENSOR
OUTDOOR AMBIENT
TEMPERA TURE SENSOR
CRANKCASE HEA TING
SV
L
PFC INDUCT OR
TH
HEA TSINK
TEMPERA TURE SENSOR
TP
EXHAUST
TEMPERA TURE SENSOR
FM1
OUTDOOR DC F AN
F AN MOT OR CAP ACIT OR
P ART NAMECODE
BLUE
BLUE
RDE
BLACK
BLACK
RDE
C N 3 0
POWER
SUPPLY
NWORB
EULB
KCALB
C N 1 6
Y/G
TO B
Y/G
TO C
Y/G
TO A
TO D
DR BOARD
CN1
4
RJ45
FOR USER
TO CONNECT
OPTIONAL
CN5
OPTIONAL
RED
BLACK
CN2
OLP TEMP . SENSOR
C N 1 4
OPTIONAL:
TOP TEMPERATURE
PROTECTION OF
COMPRESSOR
L(B) N(B) S(B) L(C) N(C) S(C) L(D) N(D) S(D)
L
N
L(A) N(A) S(A)
NWORB
NWORB
EULB
EULB
KCALB
KCALB
NWORB
EULB
KCALB
Y/GY/G
Y/G
3
3
33
3
KCALB KCALB
DER
QUAD 110 XD0C-O
NOTA: COLLEGAMENTI A CURA DELL’INSTALLATORE / NOTE: WIRING TO BE DONE BY THE INSTALLER / REMARQUE: RACCOR-
DEMENTS À LA CHARGE DE L’INSTALLATEUR / HINWEIS: VOM INSTALLATEUR AUSZUFÜHRENDER ANSCHLUSS / OPMERKING:
AANSLUITINGEN UIT TE VOEREN DOOR DE INSTALLATEUR
ATTENZIONE! La posizione dei terminali potrebbe essere dierente / WARNING! The actual shape of the components may be
dierent / ATTENTION! La position des bornes pourrait être diérente / ACHTUNG! Klemmenposition könnte abweichen / LET OP!
De positie van de eindstukken kan verschillen
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Console R32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Console R32 in the language / languages: French as an attachment in your email.

The manual is 4,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston Console R32

Ariston Console R32 User Manual - German - 43 pages

Ariston Console R32 User Manual - Dutch - 43 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info