68 /
TECHNICAL DATA
GENERAL
NOTE
Model:
CLAS ONE
CLAS NET ONE
24
30
38
CE Certication (pin)
0085CR0393
Boiler type
C13(X)-C23-C33(X)-C43(X)-C53(X)-
C63(X)C83(X)-C93(X) B23-B23P-B33
POWER SPECIFICATIONS
Max/min nominal caloric ow rate (Hi) Qn kW
22,0 / 3,7 28,0 / 4,3 31,0 / 5,5
Max/min nominal caloric ow rate (Hs) Qn kW
24,4 / 4,1 31,1 / 4,8 34,4 / 6,1
Domestic hot water max/min nominal caloric ow rate (Hi) Qn kW
26,0 / 3,7 30,0 / 4,3 38,0 / 5,5
Domestic hot water max/min nominal caloric ow rate (Hs) Qn kW
28,9 / 4,1 33,3 / 4,8 42,2 / 6,1
Max/min power output (80°C-60°C) Pn kW
21,4 / 3,4 27,4 / 3,9 30,2 / 5,2
Max/min power output (50°C-30°C) Pn kW
23,6 / 3,9 30 / 4,5 33,5 / 5,8
Domestic hot water max/min power output Pn kW
24,9 / 3,5
28,7 / 4,1 36,3 / 5,3
Combustion efciency (of ue gas) %
98,0 98,0 97,9
Nominal caloric ow rate efciency (60/80°C) (Hi) %
97,5 / 87,8 97,9 / 88,2 97,5 / 87,8
Nominal caloric ow rate efciency (30/50°C) (Hi) %
107,3 / 96,7 107,3 / 96,6 108,2 / 97,4
Efciency at 30% at 30°C %
109,8 / 98,9 109,6 / 98,7 109,7 / 98,8
Minimum caloric ow rate efciency (60/80°C) (Hi) %
93,1 / 83,8 91,1 / 82 94,4 / 85,0
Efciency rating (dir. 92/42/EEC) stars
★★★★
Sedbuk class A/90 A/90 A/90
Loss of burner gas when operating %
2,0 2,0 2,1
EMISSIONS
Available air pressure Pa 100 100 100
NoX class
class
5
Flue gas temperature (G20) (80°C-60°C)
°C
61 62 63
CO2 content (G20) (80°C-60°C) max / min
%
9,2 / 8,9
CO content (0%O2) (80°C-60°C)
ppm 141,8
123,8
106
O2 content (G20) (80°C-60°C)
%
3,9 4,2 4,3
Maximum ue gas ow (G20) (80°C-60°C)
Kg/h
42,1 48,6 61,3
Excess air (80°C-60°C)
%
23 25 26
HEATING CIRCUIT
Expansion chamber ination pressure
bar
1
Maximum heating pressure
bar
3
Expansion chamber capacity
l
8
Min/max heating temperature (high temperature range)
°C
35 / 82
Min/max heating temperature (low temperature range)
°C
20 / 45
DOMESTIC HOT WATER
CIRCUIT
Domestic hot water min/max temperature
°C
36 / 60
Specic ow rate of domestic hot water (ΔT=30°C)
l/min
12,1 14,5 18,1
Quantity of hot water ΔT=25°C
l/min
14,5 17,4 21,8
Quantity of hot water ΔT=35°C
l/min
10,4 12,5 15,5
Hot water comfort rating (EN13203)
stars
★★★
Hot water minimum ow rate
l/min
2,0 2,0 2,0
Domestic hot water max/min pressure
bar
7 / 0,2
ELECTRICAL
Power supply frequency/voltage
V/Hz
230 / 50
Total electrical power absorbed
W
77 83 84
Minimum ambient temperature for use
°C
+5
Protection level for the electrical appliance
IP
X5D
Weight
kg
29,7 32,3 34,6
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Clas One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Clas One in the language / languages: English as an attachment in your email.

The manual is 11,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info