COMMISSIONING
AUTO function
The AUTO function determines the best power output and flow tem-
perature for the heating system by continually monitoring demand.
It uses advanced modulating technology to closely track demand
and matches output with the highest precision. This ensures that
either with or without the addition of further controls the activation
of the AUTO function will enhance boiler performance. Optimum
performance can be achieved by the addition of an outdoor sensor
and indoor modulating controls.
Depending on the peripheral units connected and the number
of zones controlled, the boiler adjusts its flow temperature
automatically.
The various corresponding parameters should therefore be set (see
adjustments menu).
To activate the function, press the Auto button.
Example 1:
single zone system (high-temperature) with on/off room
thermostat:
In this case the following parameters must be set:
4 21 - Activation of temperature adjustment using sensors
- Select 1 = Basic temperature adjustment
2 44 - Boost Time (optional)
The wait time for the flow temperature increase in steps of
4°C may be set. The value varies according to the type of
system and installation.
If the Boost Time value = 00 the function is not activated.
Example 2:
single zone system (high-temperature) with on/off room
thermostat + outdoor sensor:
In this case the following parameters must be set:
4 21 - Activation of temperature adjustment using sensors
- Select 3 = outdoor sensor only
4 22 - Temperature adjustment curve selection
- Select the relevant curve according to the type of system,
installation, heat insulation used in the building, etc (see
pae 45).
4 23 - Perform a parallel curve shift if necessary, increasing or
decreasing the set-point temperature (this may also be
modified by the user, using the heating temperature
adjustment knob, which, with the Auto function activated,
is used to shift the curve in a parallel manner).
NOTE: Two zone temperature management is not suitable for use
with Y Plan systems.
NOTE: Where an outdoor sensor is connected and the system is
supplying stored domestic hot water and a central heating
circuit, each circuit must be separately connected to the PCB
using the ‘RT and ‘Cyl’ connections.
This is to ensure a correct flow temperature to the stored hot water
in the summer.
For further information please contact the Technical Help Desk on
0870 241 8180
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Clas HE R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Clas HE R in the language / languages: English as an attachment in your email.

The manual is 16,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info