719592
14
Zoom out
Zoom in
Previous page
1/24
Next page
The model 30L is covered under the Building Regulations and therefore it is not
possible to accommodate the expansion water within the system pipe work and
consequently a set of expansion controls must be installed.
Note: The discharge from relief valves must be made in a safe and conspicuous
manner; therefore a tundish (Kit C) is available for 10 and 15 litre units if required.
Please note that in all cases the dielectric junctions must be connected to the
heater before any other connection is made (these prevent an electrolytic
reaction).
Only the use of copper pipe is recommended for connection to the heater. If any
other material is used it must be able to withstand 90°C at 7 bar pressure for
long periods.
No valve must be fitted between the expansion/pressure relief valve and the
water heater.
All other required safety components to install the model 30L are supplied as a
kit with the appliance:
15mm pressure reducing valve set at 3.5bar.
Expansion vessel (charge pressure set at 3.5bar)"
c) DISCHARGE PIPE WORK NOTE:
The following guidelines refer to Building Regulation G3. It is good practice to
follow these guidlines for all relief valve discharge pipe work.
1) The tundish must be vertical and fitted within 600 mm of the temperature &
pressure relief valve and must be located with the cylinder. The tundish must also be
in a position visible to the occupants, and positioned away from any electrical devices.
The discharge pipe from the tundish should terminate in a safe place where there is
no risk to persons in the vicinity of the discharge and to be of metal.
2) Discharge pipes from the temperature & pressure relief and pressure relief valve
may be joined together.
14
Fig. 3
(Models 30L)
The tundish must be installed away from electrical devices.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Andris Lux Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Andris Lux Eco in the language / languages: English as an attachment in your email.

The manual is 2,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston Andris Lux Eco

Ariston Andris Lux Eco User Manual - Dutch - 15 pages

Ariston Andris Lux Eco User Manual - French - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info