WARNING:
- Use manual tools and equipment that are suitable for the in-
tended purpose.
- Always protect the connection cables and pipes to prevent their
being damaged, as they could cause gas leaks when damaged.
(Personal injury from cold burns).
- Recharge the refrigerant gas in accordance with the instruc-
tions provided on the product safety data sheet, while wear-
ing protective clothing and avoiding sharp bursts of gas from
the tank or from the system connections. (Personal injury from
cold burns).
1. Wrap some insulating material around the joints of the internal
unit and fasten it in place using electric (insulating) tape.
2. Fasten the extra part of the signal cable to the piping or to the ex-
ternal unit.
3. Fasten the piping to the wall (fi rst cover the pipes with electric
insulating tape) using some clips or otherwise fi t the pipes into
plastic channels.
4. Use a suitable seal to fi ll in the hole in the wall through which the
piping passes so that no air or water can fi lter through.
5. Outside, insulate all the bare piping, including all valves.
6. If the piping has to pass above the ceiling or via a warm damp
place, wrap all pipes with some extra insulating material available
on sale to prevent condensation from forming.
4.1 Testing
Check the following points:
- INTERNAL UNIT
1. Are the ON/OFF and FAN buttons working properly?
2. Is the MODE button working properly?
3. Are the buttons for the set-point and TIMER working properly?
4. Do all the LEDs come on?
5. Are the fl aps used to direct the air fl ow effi cient?
6. Is the condensation drained regularly?
- EXTERNAL UNIT
1. Is there any noise or vibration during operation?
2. Could the noise, air fl ow or condensation drainage disturb the
neighbours?
3. Are there any refrigerant leaks?
NOTE:
The electronic control will only allow the compressor to start
three minutes after the unit has been powered.
HEAT INSULATION MATERIAL
INSULATING
TAPE
PIPING
COUPLING
SEAL
OUTSIDEINSIDE
WALL
4. FINAL STAGES
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston ALYS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston ALYS in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info