566474
27
Zoom out
Zoom in
Previous page
1/94
Next page
27
GB
1 2N
S
L1
L
(A)
N
(A)
S
(A)
L
N
3. ELECTRICAL CONNECTIONS
3.1 Internal unit connection
1. Remove the terminal board cover.
2. Feed the internal unit/external unit connection cable from the rear of the internal unit
and prepare the tip of the cable.
3. Connect the conductors to the screw terminals in accordance with the numbering.
4. Use the wire clamp situated underneath the terminal board of the electrical connec-
tions.
5. Put the cover back in place, ensuring it is positioned correctly.
NOTE the connection cables must not pass near electrical boxes, wifi routers or other
cables.
3.2 External unit connection
1. Remove the cover.
2. Connect the conductors to the screw terminals using the same numbering used in the
internal unit. Screw the terminal board screws tightly to avoid any loosening.
3. Fasten the cables using the cable clamp.
4. Put the cover back in place, ensuring it is positioned correctly.
NOTE: remove the sheath from both ends of the connection wires in the cable as illus-
trated in the fi gure. Make sure the connection wires do not come into contact with the
piping or other metal parts.
Type of electrical connection
Model Power supply Switch type Connection wire power supply cable
5,5 - 8 kW
220-240V˜50Hz 16 A 4G 1,5 mm
2
3G 1,5 mm
2
11 kW
220-240V˜50Hz 25 A 4G 1,5 mm
2
3G 2,5 mm
2
NOTE: Electrical connection between the internal and external units must be performed
using a HO7RN-F cable
3.3 Connection to the electricity mains
The connection of the appliance must comply with European and national regulations and
must be protected by a 30 mA differential switch.
Connection to the electricity mains supply must be performed using a fi xed connection
(not with a mobile plug), equipped with an omnipolar switch complying with all applicable
CEI-EN regulations in force (minimum distance between contacts 3mm, switch preferably
equipped with fuses).
Proper connection to an effi cient earthing system is essential for ensuring the safe opera-
tion of the device.
15 mm
70 mm
WARNING:
- Before carrying out any electrical connection make sure that the units have been disconnected from the elec-
tricity supply and that the systems which the appliance must be connected to comply with applicable regula-
tions.
- Only use cables with a suitable section.
- Allow some extra length on the connection cables to allow for future maintenance.
- Never connect the power supply cable by cutting it in half as this could cause a blaze.
- If the power supply cable is damaged, it must be replaced by the manufacturer or by its technical assistance
service, or at least by a suitably qualifi ed individual, in order to prevent all hazards
POWER SUPPLY
(H07RN-F)
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston AERES 25 XC8-I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston AERES 25 XC8-I in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston AERES 25 XC8-I

Ariston AERES 25 XC8-I Additional guide - English - 88 pages

Ariston AERES 25 XC8-I User Manual - English - 48 pages

Ariston AERES 25 XC8-I Additional guide - Dutch - 88 pages

Ariston AERES 25 XC8-I User Manual - Dutch - 48 pages

Ariston AERES 25 XC8-I Additional guide - French - 88 pages

Ariston AERES 25 XC8-I User Manual - French - 48 pages

Ariston AERES 25 XC8-I Additional guide - Italian - 88 pages

Ariston AERES 25 XC8-I User Manual - Italian - 48 pages

Ariston AERES 25 XC8-I Additional guide - Portuguese - 88 pages

Ariston AERES 25 XC8-I User Manual - Portuguese - 48 pages

Ariston AERES 25 XC8-I Additional guide - Spanish - 88 pages

Ariston AERES 25 XC8-I User Manual - Spanish - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info