ARGUS
A
RGUS 125 141
B) CAUSE-Messages – DSS1 Protocol
Dec. Cause Description
01 Unallocated (unassigned) number No access under this call number
02 No route to specified transit network Transit network not reachable
03 No route to destination Wrong route or routing error
06 Channel unacceptable B-channel for the sending system not acceptable
07 Call awarded and being delivered in
an established channel
Call awarded and connected in an already existing channel
(e.g., X.25 SVC)
16 Normal call clearing Normal disconnect
17 User busy The number called is busy
18 No user responding No terminal equipment answered (Timer NT303 / NT310
time-out)
19 No answer from user (user alerted) Call time too long
21 Call rejected Call rejected (active)
22 Number changed Call number has been changed
26 Non-selected user clearing Incoming call not awarded to this terminal
27 Destination out of order Destination / access out of order
28 Invalid number format
(address incomplete)
Wrong call number format or call number incomplete
29 Facility rejected Facility is not supported
30 Response to STATUS ENQUIRY Response to status enquiry
31 Normal, unspecified Unspecified for "normal class" (Dummy)
34 No circuit / channel available No circuit / B-channel available
38 Network out of order Network not operational
41 Temporary failure Network is temporarily not operational
42 Switching equipment congestion Switching equipment is overloaded
43 Access information discarded Access information could not be transferred
44 Requested circuit / channel not
available
Requested circuit / B-channel is not available
47 Resources unavailable, unspecified Unspecified for “resource unavailable class” (Dummy)
49 Quality of service unavailable The requested quality of service is not available
50 Requested facility not subscribed Requested service attribute not subscribed
57 Bearer capability not authorized The requested bearer capability is not enabled
58 Bearer capability not presently
available
The requested bearer capability is not currently available
63 Service or option not available Unspecified for “service unspecified or option not
available class” (Dummy)
65 Bearer capability not implemented Bearer capability is not supported
66 Channel type not implemented Channel type is not supported
69 Requested facility not implemented Requested facility is not supported
70 Only restricted digital information
bearer capability is available
Only limited bearer capability is available
141


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argus 125 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argus 125 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info