Remove the piezometer. Fully open the plunger of the liquid valve and gas valve with the inner hex
key.
Tighten the screw caps of the valves and refrigerant charge port.
Reinstall the handle.
Leak detection
Check for leaks using a leak detector. If you do not have a leak detector you can use soapy water.
Post-installation checks
Checks Possible fault
Has the unit been installed securely? The unit could fall, move or produce excessive noise.
Has the leakage test of the refrigerant been done? Risk of condensation and dripping water.
Is the thermal insulation of the pipes sufficient? Risk of condensation and dripping water.
Does the water drain properly? Risk of condensation and dripping water.
Does the supply voltage match the voltage indicated on the
data plate?
Risk of malfunction or damage to components.
Have the piping and electrical wiring been installed
correctly?
Risk of malfunction or damage to components.
Has the unit been properly earthed? Risk of electric leakage.
Does the power cable meet requirements? Risk of malfunction or damage to components.
Are there any obstructions at the air inlet or outlet? The cooling (heating) capacity may be insufficient.
Have the dust and other particles produced during
installation been removed?
Risk of malfunction or damage to components.
Are the gas valve and liquid valve of the connecting tube
fully open?
The cooling (heating) capacity may be insufficient.
The entrance and exit of the pipe holes have been covered? Risk of condensation and dripping water.
TESTING AND OPERATION
Functional testing
Connect the power and press the ON/OFF button on the remote control to start operation.
Press the MODE button to select AUTO, COOL, DRY, FAN and HEAT mode and check the air conditioner
operates normally.
If the ambient temperature is below 16°C, the air conditioner will be unable to start cooling.
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo X3i Eco Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo X3i Eco Plus in the language / languages: English as an attachment in your email.

The manual is 3.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo X3i Eco Plus

Argo X3i Eco Plus User Manual - German - 63 pages

Argo X3i Eco Plus User Manual - French - 63 pages

Argo X3i Eco Plus User Manual - Italian - 60 pages

Argo X3i Eco Plus User Manual - Spanish - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info