665461
20
Zoom out
Zoom in
Previous page
1/27
Next page
V 11/15
20
N.B.:
• Avoid bending the drain pipe too much in order to prevent clogging.
Outdoor unit installation
Step one: secure the outdoor unit support
1. Choose a location for the unit according to the structure of the house.
2. Use expansion screws to secure the outdoor unit support in the chosen position.
N.B.:
Take the appropriate safety measures when
installing the outdoor unit.
Make sure that the bracket can support at
least four times the weight of the unit.
The outdoor unit must be connected at least
3 cm above the ground in order to install the
drain joint.
• Units with a cooling capacity of 2300 W
5000 W require 6 expansion screws; units with
a cooling capacity of 6000 W – 8000 W require
8 expansion screws; units with a cooling
capacity of 10000 W – 16000 W require 10
expansion screws.
at least 3 cm above the ground
Step two: install the drain joint
1. Connect the outdoor drain joint into the hole
on the chassis, as shown below.
2. Connect the drain hose into the drain hole.
Step three: secure the outdoor unit
1. Position the outdoor unit on the support.
2. Secure the foot holes of the outdoor unit with
bolts.
fori piedini
fori piedini
foro di scarico drain hole
tubo di scarico drain pipe
chassis chassis
giunto di scarico esterno outdoor drain joint
foripiedini foot holes
Step four: connect the indoor and outdoor pipes
1. Remove the screw on the right-hand handle
of the outdoor unit and remove the handle.
impugnatura
vite
vite screw
impugnatura handle
3. Pre-tighten the union nut by hand.
dado raccordo
giunto tubo
giuntotubo pipe joint
dado raccordo union nut
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Wall Mono 12000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Wall Mono 12000 in the language / languages: English as an attachment in your email.

The manual is 3,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Wall Mono 12000

Argo Wall Mono 12000 User Manual - German - 28 pages

Argo Wall Mono 12000 User Manual - French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info