665464
22
Zoom out
Zoom in
Previous page
1/30
Next page
V 11/15
52
sinistra
posteriore
sinistra
destra
posteriore
destra
destra right
posterioredestra rear right
sinistra left
posterioresinistra rear left
foro da
praticare
sinistra
destra
destra right
foro da praticare hole to be drilled
sinistra left
Step five: connect the indoor unit pipe
Position the pipe joint in the corresponding
bellmouth.
Pre-tighten the union nut by hand.
dado raccordogiunto tubo
tubo
giunto pipe
tubo joint
dado union
raccordo nut
Adjust the torque according to the following table. Position the open-end spanner on the pipe joint
and position the torque wrench on the union nut. Tighten the nut with the wrench.
chiave
dinamometrica
chiave
a forchetta
tubo interno
tubo
dado raccordo
chiave a forchetta open-end spanner
chiavedinamometrica wrench
tubointerno inner pipe
dado raccordo union nut
tubo pipe
Hex nut diameter Tightening torque (Nm)
6.35
15 – 20
9.52
35 – 40
tubo isolante
tuboisolante insulating tube
Wrap the indoor pipe and the joint of the
connecting pipe with an insulating tube. Then
wrap with tape.
Step six: install the condensate drain pipe
Connect the drain pipe to the outlet pipe of the
indoor unit.
Bind the joint with tape.
tuboisolante insulating tube
tubo di scarico
nastro
tubo d'uscita
tubo di
uscita
tubo di scarico
tubo di scarico
tubo isolante
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Wall Dual 12000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Wall Dual 12000 in the language / languages: English as an attachment in your email.

The manual is 2,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Wall Dual 12000

Argo Wall Dual 12000 User Manual - German - 34 pages

Argo Wall Dual 12000 User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info