459115
8
Zoom out
Zoom in
Previous page
1/88
Next page
8
EG
HOW TO SET THE PRESENT TIME
COOLING
HEATING
2.
Press the SET H button until the present time hour is
displayed.
Press the SET M button until the present time minutes
are displayed. The display will automatically stop
flashing.
1. Press the button SEL TYPE three times.
The time indication alone flashes.
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
4. Press the FAN button to select the fan speed.
ONON ON
1 H 1 H
MIN. MAX.
A
B
C
C
B
A
27
26
25
24
23
22
21
20
19
AUTOMATIC OPERATION
1
4
3
2
T
E
M
P
+
T
E
M
P
-
F
L
A
P
I
F
E
E
L
F
I
L
T
E
R
S
E
L
T
Y
P
E
S
E
T
H
S
E
T
M
T
I
M
E
R
S
E
L
F
A
N
M
O
D
E
Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1.Set the MODE selector to COOL .
2.Press the ON/OFF button and switch the
air condioner ON.
3.Press the TEMP. buttons to set the desired
temperature (the temperature range is
between 32 °C max. and 16 °C min.).
NOTE
1.Set the MODE selector to HEAT .
2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the
temperature range is between 32 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
4. Press the FAN button to select the fan speed.
For several minutes after the start of heating operation, the
indoor fan will stop until the indoor heat exchanger coil has
warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period, the
STANDBY lamp remains lit.
NOTE
DEFROSTING OF HEAT EXCHANGER
OUTDOOR UNIT “STANDBY”
When the outdoor temperature is low, frost or ice may appear
on the heat exchanger coil, reducing the heating performance.
When this happens, a microcomputer defrosting system
operates. At the same time, the fan in the indoor unit stops
and the STANDBY lamp remains lit until defrosting is completed.
Heating operation restarts after several minutes. (This interval
will vary slightly depending on the room and outdoor
temperature).
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat from
outside air. The heating efficiency will fall off when the outdoor
temperature is very low. If enough heat is not obtained with this
air conditioner, use another heating appliance in conjunction
with it.
1.Set the MODE selector to AUTO .
2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the
temperature range is between 32 °C max. and 16 °C min.).
When this setting is selected, the air conditioner calculates
the difference between the thermostat setting and the room
temperature and automatically switches to the COOL or HEAT
mode as appropriate.
4.Press the FAN selector button to the setting you want.
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
Example of operation diagram in the (Auto) mode with the set
room temperature at
23°C.
NOTE
The air conditioner changes the operation mode (from cool to heat
or vice versa, if one of the following conditions occurs:
- ZONE A: changes if the difference between the room temperature
and the temperature set on the remote control unit is at least 3°C..
- ZONE B: changes if the difference between the room temperature
and the temperature set on the remote control unit is at least 1°C,
one hour after the compressor stop.
- ZONE C: never changes if the difference between the room
temperature and the temperature set on the remote control unit is
no more than 1°C.
A-374253004-2007 7-02-2006 15:06 Pagina 8
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Ulisse HL-A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Ulisse HL-A in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 21,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info