41V 11/22
turns off. The ventilation speed will automatically switch to the lowest level available to ensure maximum quiet
operation during night rest.
Note: press the MODE button or the ON/OFF button to cancel the SLEEP function setting. The SLEEP function
cannot be activated in FAN mode.
12. SWING BUTTON (vertical oscillation)
Press this button to set the automatic vertical swing mode, which allows the outer aps to swing from top to bottom
and vice versa. Press this button again to deactivate the SWING function.
13. SWING BUTTON (horizontal oscillation)
This function is not available. However, it is possible to direct the air ow manually, by moving the aps of the
indoor unit horizontally.
14. ANTI-F BUTTON
This air conditioner has a special drying and anti-mold function. This function is controlled by the remote control in
the COOLING, DRY and AUTO modes. When the air conditioner is operating in the heating mode, the indoor
fan runs for three minutes on weak ventilation before stopping. The purpose of this function is to dry the water
inside the evaporator and prevent the formation of mold which can cause the dispersion of a strange odor. This
function is not set by default, it can be freely set and deactivated. The setting method is as follows: when the air
conditioner and remote control are off, point the remote control at the unit and press the “Anti-F” button, the unit
will beep ve times and then indicate that this function is set. Once set, this function remains valid unless the air
conditioning is completely switched off or the function is manually deactivated.
To deactivate the function:
Turn off the unit.
When the air conditioner and the remote control are off, point the remote control at the unit and press this
button, the device emits a sound three times and this indicates that the function is disabled.
Note: when this function is active, it is advisable not to restart the air conditioner before it is completely stopped.
This function will not be active if the unit is switched off or stopped by the “SLEEP” function.
15. ELE.H/ECO BUTTON
ELE.H (function not available)
ECO: if you press this button in COOL mode, the unit will activate the ECO mode which has the lowest
electricity consumption and that is automatically deactivated after 8 h. If you change the mode or turn off the
remote control, the function ECO will be automatically canceled. Press the ECO button in ECO mode to exit
this mode.
OPERATION MODE
Automatic mode (AUTO)
Press the “MODE” button, select the automatic operation mode.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH, AUTO.
Press the “ON/OFF” button, the air-conditioner starts to operate.
Press the “ON/OFF” button again, the air-conditioner stops.
COOLING mode: The default set temperature is 20 °C. When the ambient temperature exceeds 20 °C the unit starts
to operate in cooling. Below 20 ºC it only works in ventilation.
HEATING mode: The default set temperature is 25 °C. When in room the temperature is below 25 °C the unit starts
working in heating.
COOLING/HEATING mode
Press the “MODE” button, select the Cooling or Heating operation mode.
By pressing the “ “ or “ “ you can set the temperature from 16 °C to 32 °C, the display changes as you
touch the button.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH, AUTO.
Press the “ON/OFF” button, the air-conditioner starts to operate.
Press the “ON/OFF” button again, the air-conditioner stops.
FAN mode
Press the “MODE” button, select the fan operation mode.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH.
Press the “ON/OFF “ button, the air-conditioner starts to operate in FAN mode.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Newage at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Newage in the language / languages: English as an attachment in your email.

The manual is 5.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Newage

Argo Newage User Manual - Italian - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info