805050
11
Zoom out
Zoom in
Previous page
1/41
Next page
V 12/21 52
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
During heating mode It may be advisable to arrange the continuous drainage of condensate (see next chapter
CONDENSATE ELIMINATION METHOD)
Under heating mode, when the set point is reached, turn off, and internal fan motor(the upper one) keeps
operation for 10s and then stop; the external fan motor(the lower one) continues the operation at low fan speed
3. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select Dry.
The “Dry” LED on the control panel lights up
The temperature is controlled by the PCB and cannot be regulated.
In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings
and, when switched back on again, retains them.
The fan speed is set to low and cannot be adjusted.
NOTE
The air conditioner does not cool the room when it is used as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible hose must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly
into the environment.
The dehumidification mode is recommended during autumn and winter.
If used in summer, it is best to leave the flexible hose attached so that the hot air can be discharged
towards the outside rather than into the room.
During dehumidification, continuous drainage of condensate should be implemented (consult the next chapter,
"CONDENSATE ELIMINATION").
4. VENTILATION MODE (FAN ONLY)
Press the MODE button to select Fan and wait until the relative icon appears.
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
HOW TO ELIMINATE CONDENSATE
In cooling mode this appliance automatically vaporizes the condensate; only in particular climatic conditions, in which
the humidity rate of the air is very high, can it happen that water is deposited inside the internal tank. In heating it is
normal for water to be collected in the internal tank. When the internal tank is full, the air conditioner will emit 8
beeps and the display will show the message "H8", signaling the filling and blocking the operation of the
device. In Heating, it is possible, if desired, to arrange the continuous drainage of the condensate from the lower hole,
taking care to position the unit on a small rise in order to ensure the necessary slope to the drainage pipe.
Cooling and Heating
When the unit operates in the cooling and heating mode, ensure that the
rubber cap closing the drainage opening on the back of the appliance is
properly positioned.
To empty the container, switch the air conditioner off and unplug the cord.
Remove the cap from the rear drainage opening and place its end over a
normal drain. Ensure that the tube is not twisted or bent. The tube must
slope downwards. Re-close the drainage opening with the cap, insert it into
the clamp and resume use of the air conditioner.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Maxime Plus EU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Maxime Plus EU in the language / languages: English as an attachment in your email.

The manual is 3.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Maxime Plus EU

Argo Maxime Plus EU User Manual - German - 43 pages

Argo Maxime Plus EU User Manual - French - 43 pages

Argo Maxime Plus EU User Manual - Italian - 41 pages

Argo Maxime Plus EU User Manual - Spanish - 42 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info