724766
9
Zoom out
Zoom in
Previous page
1/12
Next page
9
DE
9
Num. Beschreibung Einheit
Standardwert Bereich
Erhö-
hung
Wertbeschreibung Hinweise
Boden Gebläse-
konvekto-
ren
Heizkör-
per
Min. Max.
P201 Systemtyp
(Zone2)
- 0 1 2 0 2 1 0=aufdenBoden
1=Gebläsekonvektoren
2=Niedertemperatur-Heizkörper
WennP201wirdgeändert,P205/P206/P220/
P221P223werdenaufdenentsprechendenStan-
dardwertzurückgesetzt
P205 MaximumSollwertder
Klimakurve(Zone2)
°C 35 40 40 30 55 0,5 NurfürHeizungBetriebsart
SieheGrak“KLIMAKURVE”
P206 MinimumSollwertder
Klimakurve(Zone2)
°C 20 30 30 20 40 0,5 SieheGrak“KLIMAKURVE”
P220 Temperatur für Maxi-
mumSollwert(Zone2)
°C -7 -7 -7 -20 P221 0,5 StellenSiedieminimaleerwarteteregionaleTempe-
raturein(sieheGrak“KLIMAKURVE”)
P221 Temperatur für Minimum
Sollwert(Zone2)
°C 17 17 17 P220 +35 0,5 WennP221<P220,P220wirdautomatischauf
P221gesetzt(sieheGrak“KLIMAKURVE”)
P223 KühlungSollwert(Zone
2)
°C 23 12 - 10 30 0,5 ImKühlungsbetriebistderSollwertfestundgleich
P223
P230 BerechneterSollwert
(Zone2)
°C
- - -
Nur Lesen
P231 Niedrigerer Kühlung
Sollwertmit0-10V
Steuerung(Zone2)
°C 23 12 - 10 P232 0,5 AktivenurwennP250=1,erentsprichteinem10V
Signal
SieheGrak“0-10VSTEUERUNG”
P232 HöhererKühlung
Sollwertmit0-10V
Steuerung(Zone2)
°C 30 30 - P231 30 0,5 AktivenurwennP250=1,erentsprichteinem0V
Signal
WennP232<P231,P232wirdautomatischauf
P231gesetzt(sieheGrak“0-10VSTEUERUNG”)
P250 Signalfunktion 0-10V
(Zone2)
- 0 0 0 0 2 1 0=Deaktiviert
1=ThermischeBelastung
2=Sollwertbefehl
WennP250=3o4,das0-10V-Signalwirdnurander
Ausseneinheit gelesen und die Signale der Zonen 1
und2werdenignoriert
SieheGrak“0-10VSTEUERUNG”
P251 Maximale 0-10V
Sollwertverschiebung
°C 5 5 5 1 10 0,5 AktivenurimHeizungsbetriebundwennP250=1.
EsrepräsentiertdieVerschiebungdesSollwerts
miteinem10VSignal(sieheGrak“0-10VSTEUE-
RUNG”)
P252 ManuelleSollwertver-
schiebung
°C 0 0 0 0 10 0,5 ManuelleSollwerterhöhungderKlimakurvebeider
Heizung
P260 MischventilVerzögerung sek 60 60 60 30 300 5
P261 MischventilSteue-
rungsart
- 0 0 0 0 1 1 0=230VacSteuerung(2oder3Punkte)
1=0-10VSteuerung
• UmdieZone2einzustellen,benutzenSiedieParametervonP201zuP261.
3.2.3 - ZONE 2 EINSTELLUNG
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo IM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo IM in the language / languages: German as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo IM

Argo IM User Manual - English - 12 pages

Argo IM User Manual - French - 12 pages

Argo IM User Manual - Italian - 12 pages

Argo IM User Manual - Portuguese - 12 pages

Argo IM User Manual - Spanish - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info