EG
ERROR
LEDS
OPERATION TIMER STANDBY
POSSIBLE CAUSE SYSTEM BEHAVIOUR SOLUTION
E0
l
F F
Unit has not been addressed correctly.
Operating mode selected is not
compatible with the system (ex. heating
mode has been selected, when the
system was in cooling mode, or vice
versa).
Fan is stopped and flap is closed.
The system restarts automatically
as soon as the unit is addressed
correctly.
Fan is stopped and flap is closed.
The system restarts automatically
as soon as a correct operating
mode is selected.
Set the outdoor/indoor unit refrigerant
circuit address (see Installation
Instructions)
Select an available or compatible
mode with the other units of the
system.
E1
O O F
Error on the outdoor unit. Fan is stopped and flap is closed.
The system restarts automatically
as soon as the problem on the
outdoor unit is solved.
Check the error code using the
appropriate LEDs on the PCB of the
outdoor unit.
Follow the indications of the diagnosis
for the outdoor unit.
AUTO-DIAGNOSIS TABLE
O = LED OFF
l
= LED ON F = Flashing LED
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo FC - FCIAS8DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo FC - FCIAS8DC in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo FC - FCIAS8DC

Argo FC - FCIAS8DC Installation Guide - English, German - 76 pages

Argo FC - FCIAS8DC User Manual - German - 16 pages

Argo FC - FCIAS8DC Installation Guide - French - 76 pages

Argo FC - FCIAS8DC User Manual - French - 16 pages

Argo FC - FCIAS8DC Installation Guide - Italian, Portuguese, Spanish - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info