EG
Setpoint limit setting with Heat Pump
It is possible to set the maximum achievable setpoint only with the Heat Pump. This limit can be set to 50°C or 58°C.
To change the setting, enter the con guration menu, then quickly press the BUTTON until the BLUE and YELLOW LEDs
are  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the limit is set to 50°C. We recommend to keep this setting to optimize the energy ef ciency of Emix Tank.
Antilegionella cycle setting
To activate / deactivate the Antilegionella cycle, enter the con guration menu, then quickly press the BUTTON until the
only YELLOW LED is  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default, the Antilegionella cycle is on. If the cycle is turned off, the MANUFACTURER can not be held responsible.
For details on the operation of the Antilegionella cycle, see section “ANTILEGIONELLA CYCLE”.
Temperature delta setting for restart of the heat pump
When the water temperature reaches the set value or the maximum achievable value with the heat pump alone (in the
case of Emix Tank operation without other indoor units), the heat pump switches off and starts up again only when the
water temperature drops below the desired temperature of a certain value (delta).
You can change the startup delta of the heat pump by setting it to 5°C or 10°C.
To change the set value, enter the con guration menu, then quickly press the BUTTON until the BLUE and RED LEDs
are  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the startup delta of the heat pump is set to 10°C. We recommend to keep this setting to optimize the energy
ef ciency of Emix Tank.
Reset of the factory settings
To reset all the factory settings, enter the con guration menu, then quickly press the BUTTON until the BLUE, YELLOW
and RED LEDs are  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the reset of factory settings.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
Stratifi cation sensor selection
Emix Tank measures the water temperature in the tank through one of the two strati cation sensors.
It is possible to select which of the two sensors is read for the measurement.
To change the sensor, enter the con guration menu, then quickly press the BUTTON until the YELLOW and RED LEDs
are  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the selected strati cation sensor is the upper one.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix

Argo Emix User Manual - English, German - 30 pages

Argo Emix User Manual - German - 29 pages

Argo Emix User Manual - French - 30 pages

Argo Emix User Manual - French - 29 pages

Argo Emix User Manual - Italian, Portuguese, Swedish, Spanish, Finnish - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info