665483
14
Zoom out
Zoom in
Previous page
1/30
Next page
EG
14
Supply power wire A / supply power wire for electrical heaters C:
Multipolar electric wire. Size and length of the suggested electric wire are showed on table. The wire must be
Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between the
fixing point and the terminals allows the straining of the conductors L, N before that of the grounding.
Connecting wire B (SHIELDED):
Bipolar electric shielded wire; size and length of the suggested electric wire are showed in the installation manual
of outdoor unit (consider Emix as an indoor unit).
The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).
A B C
L ( m ) S ( mm2) L ( m ) S ( mm2) L ( m ) S ( mm2)
15 4SEE OUT.UNIT 0,75 15 425 A
Connection of electrical heater elements
You must connect at least one electrical heater element of the tank to Emix.
Failure to connect at least one electrical heater element could affect the proper operation of the system; besides this, in
case of failure of outdoor unit, the electrical heaters provide heating of the water.
Connect the Electrical Heaters of the external tank to the proper connection block (ELECTRICAL HEATER R1, R2, R3 and
Neutral); Emix supports up to three Electrical elements of 1500 W each one; for connections to three-phase tanks, use
R1,R2 and R3 as the command of an electrical panel with circuit breakers.
NOTE: Emix electrical consumption is very low (max. 100W) but in case electrical heater elements are connected, Emix
has to support the ow of big amount of electrical energy; for that reason it is necessary to power Emix independently
(phase, neutral and ground) from the outdoor unit.
Back up electrical heaters’ number setting
The setting of the switch SW1 determines the number of the con-
nected electrical heater elements or the maximum number of elec-
trical heater elements that you want to use. This operation is man-
datory.
Factory setting
to be modied
1 element
Max
1,5kW
2 elements
Max
1,5 +1,5kW
3 elements
Max
1,5 + 1,5 +
1,5kW
ELECTRICAL HEATERS WIRING DIAGRAM
1 connected element More connected elements
LENGTH, SIZE OF WIRES AND DELAYED FUSE
Connection and maintenance of the supply power wire
• The electrical connection of the unit is type Y.
• The installation of the wire must be done by qualied personnel.
• If the wire is damaged by the use, for the replacement, contact After Sale Service or qualied personnel.
• The cable glands must be tightened with the proper torque to ensure IPX1 protection and to prevent the wire from
being pushed or pulled, causing dangerous situations (100N; 0.35Nm). The cable glands of the electrical resistances’
outputs must be closed with appropriate caps.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix Tank at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix Tank in the language / languages: English, German, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix Tank

Argo Emix Tank User Manual - English - 29 pages

Argo Emix Tank User Manual - German - 29 pages

Argo Emix Tank User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info