11
HYDRAULIC CONNECTION BETWEEN EMIX AND TANK
• If possible, place the tank between Emix and hydraulic system.
• If possible, place Emix at a height lower than the tank.
• Water pipes’ diameter should not be less than 20mm.
• Connect the water tank in parallel of the Emix unit (It is recommended to install service valves on the connec-
tions of the water circuit in order to make installation and maintenance operations easier):
- connect the BLUE valve of the tank with the BLUE valve of Emix
- connect the RED valve of the tank with the RED valve of Emix
• Connect the cold water inlet tap in parallel of the water port number 3 (BLUE).
• Connect the hot water tap in parallel of the water port number 4 (RED).
• Before closing the hydraulic circuit eliminate the air inside the Emix unit, purging it from the vent valves placed
inside Emix circuit.
E
Alternatively, in order to remove the air inside Emix, follow the steps below:
1. Connect completely the hydraulic system, except the cold water BLUE connection, and keep closed the
two valves.
2. Pressurize the system.
3. Slightly open the cold water valve (BLUE), keeping closed the hot water valve (RED), and vent the air from
the tting.
4. When the air is completely out and the water starts coming out, close the cold water valve (BLUE).
5. Slightly open the hot water valve (RED), keeping closed the cold water valve (BLUE), and vent the air from
the tting.
6. When the air is completely out and the water starts coming out, close the hot water valve (RED).
7. Close the hydraulic BLUE side connection of Emix.
8. Open both valves.
9. Start the system.
NOTE
NOTES
• Install the water lter supplied with Emix upstream the cold water circuit with circulation towards Emix (see arrow on
the lter).
• Install the stratication sensor supplied with Emix (see section G).
• Install a softener (or polyphosphate treatment system) to avoid limestone.
• It is suggested also the installation of a pressure reducing valve (for pressions higher than 6 bar) and a vent valve (if
necessary).
• If not already present, install a thermostatic valve for water mixing in the distribution circuit of the building.
• It is possible to install a ow switch (optional) to detect the DHW ow (see section F).
• Please always check system layouts.
FILTER
SENSOR OF
STRATIFICATION
POLYPHOSPHATE
FILTER
PRESSURE
REDUCING
VALVE
WATER MIXING
VALVE
FLOW SWITCH
NON-RETURN
VALVE
NON-RETURN
VALVE
NON-RETURN
VALVE
3 BLUE 4 RED
BLUE
RED
VALVE
VALVE
DHW
WATER SUPPLY
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix Tank at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix Tank in the language / languages: English, German, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix Tank

Argo Emix Tank User Manual - English - 29 pages

Argo Emix Tank User Manual - German - 29 pages

Argo Emix Tank User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info