665483
17
Zoom out
Zoom in
Previous page
1/29
Next page
17
EG
SWITCHES SETTING (CONTROL BOARD)
WARNING !
Power down the system before changing the settings.
SW1: SETTING OF ELECTRICAL BACKUP HEATERS
See section “Setting of electrical heater elements”.
SW3: SETTING OF TANK VOLUME
Set SW3 in order to select the water volume of the tank. SW3 is pre-set in the factory
OFF - OFF = 300 l ON - OFF = 200 l
Emix Tank unit can be used with outdoor unit G30 and G42 in a speci c con guration in order to create an heat pump
system only for DHW production.
Only DHW application: G30 / G42 + Emix Tank
Connect Emix Tank unit to the only refrigerant port (G30) or to
the refrigerant port A (G42) on the outdoor unit, using 1/4 ->3/8
adapter provided with outdoor unit.
The system will operate always in heating mode.
Remove JP1 from PCB of Emix Tank unit before switching on
the system.
In this application, you can not connect other indoor units to G42.
EMIX TANK CONNECTION- ONLY DHW APPLICATION - G30 / G42
HOW TO CONNECT EMIX TANK TO A SOLAR THERMAL SYSTEM
Emix Tank could be connected to any type of thermal solar forced circulation system (see example in the system layout).
The panel will be connected directly to the coil inside Emix Tank unit (the connections are in the lower part of the tank).
The temperature sensor of the tank for the solar thermal system can be placed in its thermowell in the lower part of the
unit (accessible by removing the lower panel - see section C).
Solar coil length: 13,2 m
Material: Fe P195GH
Diameter: 33,7mm
Surface: 1,4m
2
Position: Inside the tank
Pressure loss of solar coil
SW3 SW3
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix Tank at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix Tank in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix Tank

Argo Emix Tank User Manual - English, German - 30 pages

Argo Emix Tank User Manual - German - 29 pages

Argo Emix Tank User Manual - French - 30 pages

Argo Emix Tank User Manual - French - 29 pages

Argo Emix Tank User Manual - Italian, Portuguese, Swedish, Spanish, Finnish - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info