724568
28
Zoom out
Zoom in
Previous page
1/41
Next page
V 09/19
68
INSTALLATION WARNINGS
WARNING: Make sure that the power supply is disconnected before carrying out any work
on the unit.
WARNING: Wear appropriate personal protective equipment before carrying out any work on
the unit.
WARNING: The appliance must be reinstalled in accordance with national system
regulations.
WARNING: Wiring and installation must only be performed by a qualified technician trained
to install, modify, extend and service the unit and perform safety and functionality tests.
WARNING: Install a device, master switch or electric plug that will allow all the power from
the appliance to be switched off.
The following information is essential for correct unit installation. However, the installer
should use his or her experience to install the unit according to specific requirements.
Do not install the unit in locations where there are flammable gases or acid or alkaline
substances that may irreparably damage the copper-aluminium heat exchangers or internal
plastic components.
Do not install the unit in offices or kitchens where oil vapours mixed with treated air may
settle on the exchange coils, reducing performance, or on the unit's internal parts, damaging
the plastic components.
ATTENTION: For the connection between the units, use only annealed and deoxidized
copper pipe for conditioning and refrigeration and insulated with expanded polyethylene of
min. 8 mm.
Choosing a location for installation
Essential requirements Indoor unit
Do not install the unit in the following locations.
Otherwise, a fault may occur.
1. Locations with extreme heat sources or
flammable or explosive gases or vapours.
2
. Locations with high-frequency devices (e.g.
welding machines, medical equipment).
3. Locations close to coastal areas.
4
. Locations with oils or fumes in the air.
5. Locations with sulphide gas.
6. Other locations that have special conditions.
Do not operate the unit in the immediate vicinity
of laundrettes, bathtubs, showers or swimming
pools.
1. There should be no obstructions near the air
inlet or outlet.
2. Choose a location where the condensate can
drain out easily without causing a nuisance.
3. Choose a convenient location to connect the
outdoor unit to the power outlet.
4. Choose a location out of the reach of children.
5. The site should be strong and solid enough to
support the weight of the indoor unit and prevent
noise or vibration.
6. The unit should be installed 2.5 m from the floor.
7. Do not install the indoor unit directly above
electrical equipment.
8. Try to keep a certain distance from fluorescent
lights.
Outdoor unit
1. Choose a location where the noise and airflow produced by the outdoor unit will not annoy neighbours.
2. The location should be well ventilated and dry; the outdoor unit must not be exposed to direct sunlight
or strong winds.
3. The site should be able to support the weight of the outdoor unit.
4. Check that the installation complies with the requirements of the dimensional drawing for
installation.
5. Choose a location out of the reach of children and away from animals or plants. If this is not possible,
install safety fencing.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo ECOLIGHT SINGLE SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo ECOLIGHT SINGLE SPLIT in the language / languages: English as an attachment in your email.

The manual is 5,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo ECOLIGHT SINGLE SPLIT

Argo ECOLIGHT SINGLE SPLIT User Manual - German - 47 pages

Argo ECOLIGHT SINGLE SPLIT User Manual - French - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info