Electrical connections
1. Remove the cover of the terminal block on the right side of the outdoor unit. (one screw)
2. Connect the wires to the unit as shown in the figure, make sure that each cable is properly
connected to the terminal boards of the two units.
3. Reassemble the cover of the terminal
Insert a magneto thermic switch
with sufficient power and
observe the following table:
Magnetothermal power
switch
14K – 16A
18K 16A
21K 25A
28K 25A
To protect the unit against short circuits,
mount on the power line a magneto
thermal omni polar switch (IG) curve C
250V with a minimum contact opening of
3mm.
Wrong connection of cable may cause
malfunctions of the electrical components.
Once fixed the cables, make sure that the
lines between the links and the fixing point
are separated by some space
The connection pipes and connection
cables of units A and unit B must
correspond to each other.
The device must be installed in
accord
ance with national regulations of
wiring.
ECOLIGHT DUAL 14000 UE N
Handle
Front
side plate
To the power supply
To unit B
Power cord
To unit A
connecting
cable
L
connecting
cable
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo ECOLIGHT MULTI SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo ECOLIGHT MULTI SPLIT in the language / languages: English as an attachment in your email.

The manual is 4,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info