10
4 - GRAPHEN
4.1 - HYSTERESE ON/OFF
Rücklaufwasser-
temperatur
P130
(Sollwert)
Wärmepumpe
eingeschaltet
P02
Wärmepumpe
ausgeschaltet
4.2 - WÄRMEPUMPE BETRIEBSBEREICH/ZUSATZHEIZUNG
P40 P12
Außenluft-
temperatur
Wärmepumpe
+
Zusatzheizung
Nur
Wärmepumpe
Nur Zusatzheizung
4.3 - KLIMAKURVE (HEIZUNG BETRIEBSART)
X
Y
P105
P106
P120 P121
P130 (Sollwert)
Außenluft-
temperatur
Rücklaufwasser
Sollwert
4.4 - FROSTSCHUTZFUNKTION
Außenluft-
temperatur
P31
Frostschutzfunktion
aktiviert
Frostschutzfunktion
nicht aktiviert
P32
WenndieFrostschutzfunktionaktivist:
Rücklaufwasser-
temperatur (RWT)
5°C
Einheit in Zwangfunktion
für die Heizung
des Wassers
Einheit im
Normalbetrieb
15°C
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo AQUA UNIT - iSERIES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo AQUA UNIT - iSERIES in the language / languages: German, Portuguese, Spanish as an attachment in your email.

The manual is 2,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo AQUA UNIT - iSERIES

Argo AQUA UNIT - iSERIES User Manual - English, French, Italian - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info