Always switch off the air conditioner before unplugging
it from the power socket.
Always unplug the air conditioner before discharging
the condensate water collected inside.
WARNING
The Humidity removed by the unit is collected and
discharged automatically, but in special conditions some
condensate water could remain inside the unit.
If you are not going to make use of the air conditioner for
a long period, it is necessary to discharge the eventual
condensate water through the service cap for condensate
discharge placed under the bottom panel of the unit:
Remove the cap, after having placed a good-sized
container underneath it (at least 5-liter capacity) and
empty the condensate.
Replace the cap.
HOW TO DISCHARGE THE CONDENSATE WATER
CARE AND CLEANING
WARNING! For safety’s sake, be sure to turn the air conditioner
OFF and also disconnect it from the power supply before cleaning
it.
1. Cleaning of the Air Filter
The air filter must be checked at least once every two weeks
operation. Operation with a dirty filter always causes a lower
efficiency of the air conditioner and severe product damage.
The air filter is located on the top of the unit, under the air
intake grille:
Unhook and manually remove the air intake grille, as
shown in figure.
Remove the two filters from the filter frame.
Use a vacuum cleaner to remove light dust. If there is
sticky dust on the filter, wash them with lukewarm soapy
water, then rinse in clean, cold water and let them dry.
Replace the filters in the filter frame and close the grille.
2. Cleaning of the unit
To clean the air conditioner, wipe it with a clean soft cloth,
lightly moisted. In case it is stained, moisten the cloth with
soapy water. Never use solvents or harsh chemicals, nor very
hot water. Do not pour water over the air conditioner to clean
it: this will damage the internal components and cause an
electric shock hazard.
3. After use
If you are not going to make use of the air conditioner for a long
period, clean the air filter and verify that there is no condensate
water inside the bottom of the unit (see paragraph “HOW TO
DISCHARGE THE CONDENSATE WATER”). Do not put heavy
objects on top of the unit.
4. Transport
Keep the air conditioner in the vertical position during
transportation.
5. For your safety care check periodically the conditions
of the electric supply cable; the electrical connection of
the unit is Y type with cable prepared in a special way; in
case you should notice any damage due to usage, call the
nearest After Sale Service to get the cable replaced.
If the condensate drain system is out of order, the air conditioner display panel
will display “PU ”and give an alarm signal.
To enable the air conditioner to work temporarily until the service personnel
arrive, you can drain the water out by following the same procedure.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Apollo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Apollo in the language / languages: English as an attachment in your email.

The manual is 3,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Apollo

Argo Apollo User Manual - German - 22 pages

Argo Apollo User Manual - French - 22 pages

Argo Apollo User Manual - Italian - 22 pages

Argo Apollo User Manual - Portuguese - 22 pages

Argo Apollo User Manual - Spanish - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info