765015
94
Zoom out
Zoom in
Previous page
1/124
Next page
Replace Spaboy Output Electrode. Replace Spaboy Communication Cable.
Low ORP (Chlorine) reading detected
(Run pumps on high speed for a 20 minute cycle to mix the water. If the reading is still low move on to the next step)
Press Spaboy Boost button. Electrode will
immediately turn on for 30 minutes
Does Spaboy Output Electrode Generate smoke
during the 30 minutes period?
Reset the Spas Breaker (Turn power off and on
at the spa breaker). Spaboy will do a Polarity
Test off the Spaboy Output Electrode for 3
seconds per side immediately on Start -up
Does Electrode smoke?
Electrode Smokes for 3 seconds/
pause/3 seconds but does not stay on
for 30 minutes.
Check connection of
Spayboy Niche to
Spayboy Generator.
Check Spaboy
Generator supply
voltage direct power.
Connect Spayboy
Niche to Spayboy
Generator.
Replace Spaboy Output Electrode.
Note: If this does not correct the problem
also replace the Spaboy Niche.
Unplug Spaboy Output Electrode, test
to ensure 12-13 volts DC is maintained
indefinetly.
12-13 volts DC?
Check Spaboy Com-
munication Cable from
Generator to Pack
(Location P7, P8, P9)
Ok?
Ok?
Ok?
Replace Spaboy
Generator.
Check Spaboy fuse.
Replace Spaboy Fuse.
Replace
Motherboard.
Is Spaboy Generator
powered?
Check Spaboy volt-
age supply
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Ok?
1.13 Spa Boy® Start-Up Guide / Low ORP Troubleshooting Flow Chart
Understanding Spa Boy®
Owners Manual - Spa Boy®
9494
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arctic Spas Timberwolf at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arctic Spas Timberwolf in the language / languages: English as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info