813442
13
Zoom out
Zoom in
Previous page
1/32
Next page
Hoxton Stove User Guide
BK755 Page 13
5.1.4 Secondary Air Control
The control has an internal rotary plate with slots housed inside the body of the appliance,
and is located below the left hand corner of the fire door assembly, when looking at the
front of the appliance.
Sliding the control knob to the right as far as it will go, achieves the fully open position, see
Figure 3. Sliding it to the left will reduce or shut down the air as shown in Figure 4.
NOTE : If your stove installation is within a smoke control area, it will be fitted with a
restrictor plate acting as a mechanical stop for the secondary air control. This will not
fully close, thus allowing a bleed of air to the fire box to reduce smoke
emissions.
5.1.5 Tertiary Air
All models have tertiary air supply that can be seen working in certain conditions during the
burning period. The outlet for the tertiary air is at the rear of the fire box chamber, located
below the throat plate on the rear of the firebox.
Air is emitted through a series of small holes within this metal chamber.
Tertiary air is employed to provide additional air to the upper areas of the fire box, to
promote additional burning of the unburnt combustion gases and thus ensuring a cleaner
burn emission.
Generally there is no user adjustment required, however if a high flue draw is measured
upon installation, then a slider is fitted to provided control, this would be set by the
installation engineer.
PLEASE NOTE: The tertiary slider is factory set to maximum open (Lever fully to left when
looking at the rear of stove). To adjust, remove the rear heatshield and slacken the 4x nuts,
just enough to allow the slider to move, adjust & retighten nuts and replace the heatshield.
Figure 3. Fully Open Position Figure 4. Reduced / Closed Position
Tertiary Air Inlet
Reduce Tertiary Air
Retaining Nuts X4
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Hoxton at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Hoxton in the language / languages: English as an attachment in your email.

The manual is 1.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info