813440
5
Zoom out
Zoom in
Previous page
1/40
Next page
SAFETY NOTICES
A fireguard should be used in the presence of
children and elderly or infirm people.
Please note, This appliance should be used
with the fire door closed at all times except
when re-fuelling or de-ashing.
REMEMBER THE STOVE IS VERY HOT DURING
OPERATION. KEEP CHILDREN, CLOTHING
AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
Do not use aerosol sprays or any other
flammable materials near the appliance
under fire.
Do not fit an extractor fan in the same
room as the appliance.
Fire cement is caustic, hand and eye
protection should always be worn,
prolonged contact with the skin should be
avoided.
Arada Ltd will not be responsible for any
consequential or incidental loss or
injury however caused.
Before continuing any further, with the
installation of this appliance please read the
following guide to manual handling.
Always obtain assistance when lifting the
appliance
When lifting always keep your back straight,
bend your legs not your back
Avoid twisting at the waist. It is better to
reposition your feet.
Avoid upper body/top heavy bending. Do
not lean forwards or sideways when
handling the fire
Always grip with the palms of your hands
do not use your fingertips for support
Always keep the stove as close to the body
as possible as this will minimise the
cantilever action.
Use gloves to provide additional grip.
THE PRINCIPLE OF THE STOVE
Your Arada stove is built to the highest
standard of craftsmanship using the best
materials and the most modern equipment
available. It is a highly efficient and sophisticated
piece of machinery and when properly installed
and operated should provide a lifetime of
heating satisfaction.
Safety is the most important consideration when
installing your fire. If not properly installed and
operated a house fire may result. Installation
must comply with the Building Regulations and
conform to all safety standards.
Arada produce a variety of appliances ranging
from the traditional to the modern in style and
appearance.
The fire door is fitted with a special high
temperature ceramic glass panel through which
the fire can be viewed.
The stove is lined with firebricks or heat
reflective panels which ensure complete
combustion and provide a good heat store to
even out fluctuations in burning.
An internal throat plate produces turbulence to
encourage secondary combustion and direct the
flue gas around the whole upper firebox before
allowing it to escape up the chimney.
Grate Bars
The Farringdon 16 wood stove is fitted with a
riddling grate system to support the fuel above
the ash pit containing the removable ash pan.
The stove is designed to burn wood only on
the grate and the stove MUST NOT be used
without the grate fitted. Spare grate bars are
available see page 32 for part number details
Arada stoves are also fitted with an air washso
called because it provides a curtain of high
speed preheated air behind the glass to help
keep it clean and provide secondary air/over
draught.
Arada Farringdon 16
INTRODUCTION
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Farringdon 16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Farringdon 16 in the language / languages: English as an attachment in your email.

The manual is 4.6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Arada Farringdon 16

Arada Farringdon 16 User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info